First startup
3.1. Preparation before starting up
Put oil on the motor (Fig.1) using 15W40 oil, 1.6Lt maximum, check the
level with the dipstick without screwing it in, the level must remain the
the maximum line (without exceeding the upper mark).
Fill the fuel tank with diesel (Fig 2), with 17 liters (depending on the version).
Connect the positive (red wire) to the battery, insert it back into its housing,
pay attention not to touch the positive to the body or it could blow the fuse.
Tape the positive terminal if necessary.
Be sure to remove the lateral battery caps. (Fig 3)
3.2
Starting the Generator
Turn the speed lever to the "RUN" position. (Fig 4)
It is possible that the first time you need to purge air from circuit by removing
the rubber tube indicated (Fig.5), letting flow the diesel. When no air, put back
in place, and do not touch the pressure tubes. Repeat if necessary.
Insert the key into the bowler and proceed to startup. Turn right to the "ON"
position to give contact. Turn the key to the START position to start the
engine (Fig 6).
Once the generator is running, make it work for 3 minutes and make sure
the differential is at the "OFF" position (down). Then you can connect the
load and put the differential at the "ON" position.
RESPECT THE GENERATOR'S RATED POWER. IF THERE'S AN OVERLOAD THE
BREAKER WILL JUMP BETWEEN 3 AND 10 SECONDS.
WHEN THE GENERATOR IS RUNNING THE DIGITAL DISPLAY LED 5 WILL
SHOW YOU THE VOLTAGE, FREQUENCY, THE HOURS OF USE AND THE
APPLIED POWER.
3.3
Stopping the generator
Turn the differential to the "OFF" position (down, Fig 7) and disconnect the
equipment connected to the control panel.
(If you miss this step, you may damage the voltage regulator AVR).
To stop the engine, turn the key ) to "OFF" position.