Compaq ProLiant ML350 G2 Service Overview

Tower to Rack Conversion

System configuration switch 3 must be set to indicate whether the server is being deployed as a
tower or a rack. If the switch is off, the server is configured as a tower. If it is on, the server is
configured as a rack.
Table 9: System Models
Rev. 1.0
Switch
Default
1
Off
2
Off
3
Off
4
Off
5
Off
6
Off
7
Off
8
Off
Function
Off = Video enabled
On = Video disabled
Off = Normal operation
On = Configuration locked
Off = Tower
On = Rack
Off = Normal
On = Enable diskette boot
Off = Normal
On = Password disable
Off = Normal
On = Configuration erased
Reserved
Reserved
22