Item
Condition
10.DTMF
1) Adj item:[W DTMF Dev]
deviation
Adjust:[***]
adjust
Deviation meter filter
•Wide
LPF:15kHz
(Concentric SW:A)
HPF:OFF
PTT:ON
Press [B] to store the adjustment
value after adjustment.
•Narrow
2) Adj item:[N DTMF Dev]
(Concentric SW:B, C)
Adjust:[***]
PTT:ON
Press [B] to store the adjustment
value after adjustment.
11.Single tone 1) Adj item:[W Tone Dev]
deviation
Adjust:[***]
adjust
Deviation meter filter
•Wide
LPF:15kHz
(Concentric SW:A)
HPF:OFF
PTT:ON
Press [B] to store the adjustment
value after adjustment.
•Narrow
2) Adj item:[N Tone Dev]
(Concentric SW:B, C)
Adjust:[***]
PTT:ON
Press [B] to store the adjustment
value after adjustment.
12.MSK
1) Adj item:[W MSK Dev]
deviation
Adjust:[***]
adjust
Deviation meter filter
•Wide
LPF:15kHz
(Concentric SW:A)
HPF:OFF
PTT:ON
Press [B] to store the adjustment
value after adjustment.
•Narrow
2) Adj item:[N MSK Dev]
(Concentric SW:B, C)
Adjust:[***]
PTT:ON
Press [B] to store the adjustment
value after adjustment.
13.BATT
1) Adj item:[Battery]
TX inhibit
Adjust:[***]
voltage
PTT:ON
adjust
14.BATT
[Panel test mode]
TX inhibit
1) CH-Sig:1-1
voltage
BATT terminal voltage:6.0V
Check
PTT:ON
BATT terminal voltage:5.8V
PTT:ON
ADJUSTMENT
Measurement
Test-
Unit
Terminal
equipment
Power meter Panel
ANT
Deviation
Universal
meter
connector
Oscilloscope
AG
AF VTVM
Power meter Panel
ANT
DVM
BATT
terminal
Adjustment
Unit
Parts
Method
Panel
[C],[D]
3.0kHz
1.5kHz
3.0kHz
1.5kHz
3.0kHz
1.5kHz
Panel
After pressing the BATT terminal voltage:5.8V
PTT switch, confirm
that one predetermined
numeric in the range
1 to 256 appears and
then press [B] key.
That numeric will be
stored in memory.
Check
TK-5210
Specifications/Remarks
±50Hz
±50Hz
±50Hz
±50Hz
±50Hz
±50Hz
The transceiver can
transmit and the red
LED blinking.
The transceiver cannot
transmit.
53

Advertisement

Table of Contents
loading

Table of Contents