Kenwood TK-5210 Service Manual page 53

Vhf p25 transceiver
Hide thumbs Also See for TK-5210:
Table of Contents

Advertisement

TK-5210
Item
7. P25 high
1) Adj item:[A APCO Hi Dev]
deviation
Adjust:[***]
adjust
Deviation meter filter
LPF:3kHz
HPF:OFF
2) Adj item:[AL APCO Hi Dev]t
[ALC APCO Hi Dev]t[AC APCO Hi Dev]t
[ACH APCO Hi Dev]t[AH APCO Hi Dev]
PTT:ON
Press [B] to store the adjustment
value after adjustment.
8. QT deviation 1) Adj item:[W QT Dev]
adjust
Adjust:[***]
•Wide
Deviation meter filter
(Concentric SW:A)
LPF:3kHz
HPF:OFF
2) Adj item:[WL QT Dev]t
[WLC QT Dev]t[WC QT Dev]t
[WCH QT Dev]t[WH QT Dev]
Adjust:[***]
PTT:ON
Press [B] to store the adjustment
value after adjustment.
•Narrow
3) Adj item:[N QT Dev]
(Concentric SW:B,C)
Adjust:[***]
PTT:ON
Press [B] to store the adjustment
value after adjustment.
9. DQT
1) Adj item:[W DQT Dev]
deviation
Adjust:[***]
adjust
Deviation meter filter
•Wide
LPF:3kHz
(Concentric SW:A)
HPF:OFF
2) Adj item:[WL DQT Dev]t
[WLC DQT Dev]t[WC DQT Dev]t
[WCH DQT Dev]t[WH DQT Dev]
Adjust:[***]
PTT:ON
Press [B] to store the adjustment
value after adjustment.
•Narrow
3) Adj item:[N DQT Dev]
(Concentric SW:B, C)
Adjust:[***]
PTT:ON
Press [B] to store the adjustment
value after adjustment.
52
ADJUSTMENT
Measurement
Condition
Test-
equipment
Power meter Panel
Deviation
meter
Oscilloscope
AG
AF VTVM
Adjustment
Unit
Terminal
Unit
Parts
ANT
Panel
[C],[D]
Universal
connector
Specifications/Remarks
Method
2827Hz
2771~2883Hz
0.75kHz
±50Hz
0.375kHz
±50Hz
0.75kHz
±50Hz
0.375kHz
±50Hz

Advertisement

Table of Contents
loading

Table of Contents