Kenwood TK-5210 Service Manual page 52

Vhf p25 transceiver
Hide thumbs Also See for TK-5210:
Table of Contents

Advertisement

Item
Condition
4. MIC
1) Adj item:[Mic Sense]
sensitivity
Adjust:[129]
check
PTT:ON
Press [B] to store the adjustment AG
value after adjustment.
5. DQT balance 1) Adj item:[W Balance]
adjust
Adjust:[***]
•Wide
Deviation meter filter
(Concentric SW:A)
LPF:3kHz
HPF:OFF
2) Adj item:[WL Balance]t
[WLC Balance]t[WC Balance]t
[WCH Balance]t[WH Balance]
Adjust:[***]
PTT:ON
Press [B] to store the adjustment
value after adjustment.
•Narrow
3) Adj item:[N Balance]
(Concentric SW:B)
Adjust:[***]
PTT:ON
Press [B] to store the adjustment
value after adjustment.
•P25
4) Adj item:[A Balance]
(Concentric SW:C)
Adjust:[***]
PTT:ON
Press [B] to store the adjustment
value after adjustment.
6. Max DEV
1) Adj item:[W FM Max Dev]
adjust
Adjust:[***]
•Wide
AG:1kHz/150mV at MIC terminal
(Concentric SW:A)
Deviation meter filter
LPF:15kHz
HPF:OFF
2) Adj item:[WL FM Max Dev]t
[WLC FM Max Dev]t[WC FM Max Dev]t
[WCH FM Max Dev]t[WH FM Max Dev]
Adjust:[***]
PTT:ON
Press [B] to store the adjustment
value after adjustment.
•Narrow
3) Adj item:[N FM Max Dev]
(Concentric SW:B, C)
Adjust:[***]
PTT:ON
Press [B] to store the adjustment
value after adjustment.
ADJUSTMENT
Measurement
Test-
Unit
Terminal
equipment
Deviation
Panel
ANT
meter
Universal
Oscilloscope
connector
AF VTVM
Adjustment
Unit
Parts
Method
Adjust AG input 15mV±3.5mV
to get a standard Note:The SSW terminal
MOD., 3.0kHz.
Panel
[C],[D]
Make the
demodulation
waves into
square waves.
4.0kHz
(According to the
large +, -)
2.0kHz
(According to the
large +, -)
TK-5210
Specifications/Remarks
(pin1) of the universal
connector must be
connected to GND
when checking the
MIC sensitivity
±50Hz
±50Hz
51