International Regulatory Requirements - Avaya 8800 Installation Manual

Ethernet routing switch chassis installation
Table of Contents

Advertisement

Technical specifications
Table 38: 8006 environmental specifications
Operating temperature
Storage temperature
Operating humidity
Storage humidity
Operating altitude
Storage altitude
Free fall/drop
Vibration
Shock/bump

International regulatory requirements

The 8006 chassis conforms to the following international regulatory requirements:
Electromagnetic emissions
Electromagnetic immunity
Safety agency certification
Electromagnetic emissions
The 8006 chassis conforms to the following electromagnetic emissions standards.
Table 39: 8006 electromagnetic emissions
Global basis for certification
US
Canada
Europe
Australia/New Zealand
98
Installation — Chassis
Parameter
on page 98
on page 99
on page 99
Parameter
Comments? infodev@avaya.com
Specification
0°C to 40°C (32°F to 104°F) short-term exceptional
operating temperature: 55C for a maximum of 96
hours
– 25°C to 70°C (– 13°F to 158°F)
85% maximum relative humidity, noncondensing
short-term exceptional operating humidity: 93%
relative humidity at 40C for a maximum of 96 hours
95% maximum relative humidity, noncondensing
3048 m (10 000 ft) maximum
3048 m (10 000 ft) maximum
ISO 4180-s, NSTA 1A
IEC 68-2-6/34
IEC 68-2-27-29
Specification
CISPR 22-1997 Class A
FCC CFR47 Part 15, Subpart B, Class A
ICES-003, Issue-2, Class A
EN 55022-1998 Class A; EN 61000-3-2/A14,
EN 61000-3-3 (CE Marking)
AS/NZS 3548:1995, Class A