2.4.3

"USB Configuration"

Calling "USB Configuration"
Select: "Setup Utility (Page 9)" > "Advanced" > "USB Configuration".
Firmware setting
USB Per-Port Control
2.4.4

"Miscellaneous Configuration"

Calling "Miscellaneous Configuration"
Select: "Setup Utility (Page 9)" > "Advanced" > "Miscellaneous Configuration".
Firmware setting
Value
HPET - HPET Sup-
Enabled
port
Disabled
2.4.5

"Video Configuration"

Calling "Video Configuration"
Select: "Setup Utility (Page 9)" > "Advanced" > "Video Configuration".
Firmware setting
Value
Boot prime display
GOP Default
control
DPP(X71)
DPP(X70)
Panel Only
Rotate Screen
Disabled
90
270
: Only visible on the panel PC.
1
Firmware/BIOS description SIMATIC IPC227G, IPC277G
Operating Instructions, 05/2021, A5E50059883-AA
Value
Setting in delivery state
IPC227G
IPC277G
Enabled
Disabled
Setting in delivery state Meaning
IPC227G
IPC277G
x
Setting in delivery state
IPC227G
x
1
x
Meaning
Each USB port can be controlled individually.
x
All the USB ports cannot be controlled.
x
The High Precision Event Timer can be used by operating
system.
The High Precision Event Timer cannot be used by operating
system.
Meaning
IPC277G
Set as current GOP setting.
DisplayPort video is used.
DisplayPort video is used.
x
Display on the panel.
The rotate screen feature is disabled.
Support rotating screen 90 degrees clockwise.
Support rotating screen 270 degrees clockwise.
Configure firmware
2.4 "Advanced" tab