Strain gauge converter with
modbusrtu protocol (18 pages)
Summary of Contents for Seneca S117P1
Page 1
INSTALLATION MANUAL S117P1 Asynchronous serial converter RS232 / USB, TTL / USB and RS485 / USB SENECA s.r.l. Via Austria, 26 – 35127 – PADOVA – ITALY Tel. +39.049.8705355 - 8705359 - Fax +39.049.8706287 For manuals in other languages and configuration software, visit: www.seneca/products/s117p1...
Compatible with standard USB port 1.0, 1.1 and 2.0. • Insulation between USB and RS232 or TTL or RS485: 1500 V • 12 Vdc @ 100 mA available from terminals to supply a seneca module • Supply through the PC USB. •...
TECHNICAL SPECIFICATIONS EN61000-6-4 Electromagnetic emissions, industrial environment. EN61000-6-2 Electromagnetic immunity, industrial environment. STANDARDS EN61010-1 Safety WARNING RS232 the maximum working voltage between any Input terminal and ground must be less than 50 Output RS485 INSULATION Vac / 75Vdc Power Supply In/Out 1500 V -20 –...
INSTALLATION REGULATIONS As regards the S117P1 instrument, there are no particular precautions to follow, except that of using a shielded cable for the RS232 and RS485 lines for long connections or connections in noisy environments. TERMINAL POSITION AND DESCRIPTION The drawing below shows the functions of the removable screw connector on the side of the S117P1:...
DRIVER INSTALLATION The user is provided with a CD containing the instrument driver. In this section we will describe in detail the driver installation procedure. It should be noted that the installation in Linux environments (with Kernel 3.0.0-19 or later) is automatic and does not require the driver CD.
Page 7
If the installation does not start automatically, you will have to proceed manually, following the instructions given. First of all you need to have an internet connection allowing the instrument to perform the driver update following the automatic procedure or by connecting (http://www.ftdichip.com/Drivers/VCP.htm). For the automatic proce- dure, configure as in Fig 3.
Product information commerciale@seneca.it This document is the property of SENECA srl. Copies and reproduction are prohibited unless authorised. The con- tent of this document corresponds to the described products and technologies. Stated data may be modified or supplemented for technical and/or sales purposes.
Need help?
Do you have a question about the S117P1 and is the answer not in the manual?
Questions and answers