Download Print this page

Pentair INVERTEMP IVTP-1M-DB Installation And Operating Manual page 3

Advertisement

TABLE OF CHARACTERISTICS
Model
IVTP-1M-DB
IVTP-2M-DB
Modèle
IVTP-1M-DB
IVTP-2M-DB
Conditions
Dry air temperature: 28°C - Relative humidity: 80% - Input water temperature: 28°C
Heating capacity
6,8 kW
8,8 kW
(boost Mode)
Continuous power (COP)
5,9 - 6,5
5,5 - 6,5
(boost Mode)
Heating capacity
3,2 - 6,8 kW
3,5 - 8,8 kW
(Smart mode)
Continuous power (COP)
5,9 - 10,8
5,5 - 10,8
(Smart mode)
Heating capacity
3,2 - 5,8 kW
3,5 - 5,8 kW
(Eco mode)
Continuous power (COP)
8,3 - 10,8
8,3 - 10,8
(Eco mode)
Conditions
Dry air temperature: 15°C - Relative humidity: 70% - Input water temperature: 28°C
Heating capacity
5,4 kW
6,6 kW
(boost Mode)
Continuous power (COP)
4,5 - 4,8
4,4 - 4,9
(boost Mode)
Heating capacity
2,6 - 5,4 kW
3,2 - 6,6 kW
(Smart mode)
Continuous power (COP)
4,5 - 6,7
4,4 - 6,7
(Smart mode)
Heating capacity
2,6 - 2,9 kW
3,2 - 3,8 kW
(Eco mode)
Continuous power (COP)
5,6 - 6,7
5,6 - 6,7
(Eco mode)
Dry air temperature: 7°C - Relative humidity: 0% - Input water temperature: 26°C
Conditions
Heating capacity
2,75 kW
3,35 kW
Continuous power (COP)
2,86
2,82
Sound pressure at 10m
22-32 dB(a)
24-33 dB(a)
Compressor
Expansion valve
Cabinet
Reinforced ABS, UV protection and equipped with soundproof panels
Refrigerant
Hydraulic connection
Supply voltage
Fuse rating
C 10 A
C 10 A
Power supply cross section
3G 2,5 mm²
3G 2,5 mm²
Minimum water flow
4 m³/h
Weight
38 kg
38 kg
2
IVTP-3M-DB
IVTP-4M-DB
IVTP-5M-DB
IVTP-3M-DB
IVTP-4M-DB
IVTP-5M-DB
10,6 kW
12,8 kW
16,5 kW
5,4 - 6,8
5,6 - 6,8
5,1 - 6
3,9 - 10,6 kW
4,2 - 12,8 kW
5,5 - 16,5 kW
5,4 - 10,8
5,6 - 11,2
5,1 - 10,8
3,9 - 7,1 kW
4,2 - 8,4 kW
5,5 - 9,9 kW
8,3 - 10,8
8,5 - 11,2
8,3 - 10,8
7,8 kW
9,8 kW
11,5 kW
4,9 - 5,2
4,5 - 5
4,2 - 4,6
3,5 - 7,5 kW
3,7 - 9,8 kW
4,2 - 11,5 kW
4,9 - 6,7
4,5 - 7,0
4,2 - 6,7
3,5 - 4,9 kW
3,7 - 7,8 kW
4,2 - 6,7 kW
6,1 - 7,1
5,5 - 7,0
5,7 - 6,7
4,65 kW
5,45 kW
5,8 kW
3,96
3,64
2,83
27-34 dB(a)
28-39 dB(a)
28-39 dB(a)
Mitsubishi / Toshiba 2D Full DC Inverter
Electronic
Recyclable refrigerant with no impact on the ozone layer (R32)
1,5" / 50 mm
230V / 1 +N / 50 Hz
C 10 A
C 16 A
C 20 A
3G 2,5 mm²
3G 2,5 mm²
3G 4 mm²
5 m³/h
44 kg
44 kg
54.5 kg
DELIVERY TRANSPORT
IVTP-6M-DB
IVTP-6M-DB
When you have unpacked the HP, please check the content to report any damage. Please also check that the pressure reading on the pressure gauge is equal to
the pressure mentioned on the box, depending on the measured outdoor temperature, as different values might indicate a leak.
20,1 kW
The HP should always be stored and transported in a vertical position, on a pallet and inside its original packaging.
5,2 - 5,9
Transporting and/or storing the HP horizontally will void the guarantee.
GENERAL DESCRIPTION
6,5 - 20,1 kW
5,2 - 10,1
Manufacturer' s plate
6,5 - 12,2 kW
8,1 - 10,1
Pressure gauge
Control screen
14,6 kW
4,3 - 4,6
4,9 - 14,6 kW
4,3 - 6,6
230V AC electric
supply inlet
4,9 - 8,5 kW
RS485 cable passage
5,6 - 6,6
(option)
8,3 kW
3
Side protective grids of the evap-
29-40 dB(a)
C 20 A
3G 4 mm²
6 m³/h
62.5 kg
Rear protective grid of the evaporator
30
25
35
20
49
40
42
56
15
33
28
62
45
23
67
10
17
10
72
50
0
R32 static °C / bar
5
-9
-20
Classe 1.6
55
°C
10 bar = 1 MPa = 145 psi
Bar
0
60
OUT
InverTemp™-DB 1M
QC Passed
MADE IN CHINA
IVTP-1M-DB
Pentair International Sarl
Avenue de Sévelin 18
S/N 1234ABCD1234ABCD1234ABCD01
Mfg Year
ME
SCAN
CH-1004 Lausanne
230V 50Hz~ / IPX4 / 2400 W
Nov-2019
IN
Water inlet
Hot water outlet
orator
Remote fan air outlet
Condensate evacuation
Installation pads
(under hoods)
3

Advertisement

loading

This manual is also suitable for:

Invertemp ivtp-2m-dbInvertemp ivtp-3m-dbInvertemp ivtp-4m-dbInvertemp ivtp-5m-dbInvertemp ivtp-6m-db