Summary of Contents for Pool Technologie Justsalt Uno

  • Page 1 Instructions for use Electrolyseur de sel Salt chlorinator PAPI004102-M - Version 20.10...
  • Page 2: Table Of Contents

    SOMMAIRE FRANCAIS ........................... 2 ............................3 3. INTERFACE DU COFFRET ELECTRONIQUE ........................4 3.1. Clavier ................................... 4 3.2. Indicateurs ................................4 3.2.1. Voyants ..............................4 3.2.2. Ecran ................................ 4 3.3. Navigation dans les menus ........................... 5 3.4. Fonctionnalités ..............................6 3.4.1.
  • Page 3 -ci. Le bidon de correcteur pH doit être suffisamment éloigné de tout appareillage électrique et de tout autre produit chimique. LEGENDE : 1 : Capteur sel / température (en option) 2 : Cellule : blanc. 3 : Coffret électronique : blanc + gris. 4 : Filtre lesteur : blanc + gris + noir.
  • Page 4: Interface Du Coffret Electronique

    3. INTERFACE DU COFFRET ELECTRONIQUE 3.1. Clavier TOUCHE DE COMMANDE (Pictogramme de référence FONCTION dans cette notice) Mise (faire un appui long). La production, avec ou sans contrôle ORP, démarre automatiquement 2 minutes après la mise en marche. Si une alarme est déclenchée, appuyer préalablement sur Lancement du mode Boost.
  • Page 5: Navigation Dans Les Menus

    3.3. Navigation dans les menus * Affichage initial par défaut / à la mise sous tension du coffret, au bout de quelques secondes. Légende : : blanc. : blanc + gris. : blanc + gris + noir.
  • Page 6: Fonctionnalités

    3.4. Fonctionnalités 3.4.1. Menu Réglages possibles Réglage par défaut Français Italiano English Nederlander Français Deutsch Portugués Español Tcheque 3.4.2. Menu Réglages possibles Réglage par défaut Jour / Mois / Année aléatoire Heure / Minute 3.4.3. Spécification du volume de la piscine Menu Réglages possibles Réglage par défaut...
  • Page 7: Ajustage De La Mesure Du Taux De Sel

    3.4.6. Si le capteur température est désactivé, le menu ci- Menu Réglages possibles Réglage par défaut De - à + 5°C par rapport à la mesure affichée, par pas de 1. Mesure affichée 3.4.7. Ajustage de la mesure du taux de sel Si le capteur sel est désactivé, le menu ci- Menu Réglages possibles...
  • Page 8: Réglage De La Consigne De Production

    3.4.11. Réglage de la consigne de production Mode de Menu fonctionnement Réglage Instructions spécifiques Réglages possibles (selon modèle) par défaut Sélectionner directement une valeur avec les touches De 0 à 100 %, par pas de 10. 100 % Pas de validation requise. 3.4.12.
  • Page 9: Etalonnage Des Sondes : Informations Préalables Importantes

    3.4.15. Etalonnage des sondes : informations préalables importantes de la remise en service, et après chaque remplacement de sonde. 3.4.16. Etalonnage de la sonde pH (solution pH 7 + solution pH 10)" usage unique). 3) Si la sonde est déjà installée : a) Extraire la sonde du porte-sonde, sans la débrancher.
  • Page 10: Activation/Désactivation De La Régulation Ph

    6) Effectuer la navigation avec les instructions ci-dessous : puis patienter quelques minutes. Ne pas toucher la sonde. (Patienter quelques instants) b) Installer la sonde dans le porte-sonde. Effectuer une seconde fois la navigation avec les instructions ci-dessus. seconde fois, remplacer la sonde puis effectuer de nouveau un étalonnage.
  • Page 11: Test Automatique Du Coffret Électronique Et De La Cellule

    3.4.20. Test automatique du coffret électronique et de la cellule Ce test est destiné aux Menu Navigation (Patienter quelques instants) Faire un appui long. Intensités et tensions alimentant la cellule, sur chaque sens (valeurs purement indicatives). 3.4.21. Réinitialisation des paramètres Menu Mise en garde importante La réinitialisation des...
  • Page 12: Alarmes

    3.5. Alarmes Toute alarme qui se déclenche : avec la touche N (appui court ou long - peut être désactivée (sauf « »), en désactivant le capteur associé au défaut détecté (menu « »). Les « » et « » stoppent automatiquement et instantanément la régulation pH.
  • Page 13: Garantie

    4. GARANTIE Avant tout contact avec votre revendeur, merci de bien vouloir vous munir : - du n° de série du coffret électronique. - de la date d'installation de l'équipement. - des paramètres de votre piscine (salinité, pH, taux de chlore, température d'eau, taux de stabilisant, volume de la piscine, temps de filtration journalier, etc.).
  • Page 14 TABLE OF CONTENTS ENGLISH 1. FUNCTIONS OF THE EQUIPMENT ..........................2 2. INSTALLATION DIAGRAM ............................. 3 3. ELECTRONICS UNIT INTERFACE ............................ 4 3.1. Keypad .................................. 4 3.2. Indicators ................................4 3.2.1. LEDs ................................. 4 3.2.2. Screen ..............................4 3.3. Menu navigation ..............................5 3.4.
  • Page 15: Installation Diagram

    2. INSTALLATION DIAGRAM The electrical connections at cell-level must not point upwards, to avoid any deposits of water or humidity on them. The pH corrector container must be installed a safe distance away from any electrical device or any other chemicals.
  • Page 16: Electronics Unit Interface

    3. ELECTRONICS UNIT INTERFACE 3.1. Keypad COMMAND KEY (Reference pictogram FUNCTION in these instructions) Switching on and off (press and hold). Production, with or without ORP control, starts automatically 2 minutes after switching on. When switching off, the screen then the green LED will also turn off. If an alarm has been activated, press first on to switch off.
  • Page 17: Menu Navigation

    3.3. Menu navigation * Initial display by default / upon connection of the unit to a power supply, after a few seconds. Key : : white. : white + grey. : white + grey + black.
  • Page 18: Features

    3.4. Features 3.4.1. Selecting the display language Menu Possible settings Default setting Français Italiano English Nederlander Français Deutsch Portugués Español Tcheque 3.4.2. Setting the date and time Menu Possible settings Default setting Day / Month / Year random Hour / Minute 3.4.3.
  • Page 19: Calibration Of The Water Temperature Measurement

    3.4.6. Calibration of the water temperature measurement If the temperature sensor is disabled, the menu below does not appear. Menu Possible settings Default setting From - to + 5°C compared to the measurement displayed, in increments of 1. Measurement displayed 3.4.7.
  • Page 20: Setting The Production Setpoint

    3.4.11. Setting the production setpoint Menu Chlorinator Default (depending on Specific instructions Possible settings operating mode setting model) Select a value with the buttons. From 0 to 100 %, No confirmation required. 100 % in increments of 10. 3.4.12. Setting the pH setpoint Menu Possible settings Default setting...
  • Page 21: Calibrating The Probes : Important Advance Information

    3.4.15. Calibrating the probes : important advance information The original pH probe is already calibrated. It is therefore not necessary to carry out calibration of the pH probe when putting the equipment into service for the first time. However, it is imperative to carry out a calibration of the pH and ORP probes at the beginning of each season when returning to service, and after each probe replacement.
  • Page 22: Activation/Deactivation Of Ph Regulation

    6) Navigate through the menus following the instructions below : Insert the probe into the ORP calibration solution, then wait a few minutes. Do not touch the probe. (Wait a few seconds) a) Rinse the probe under running water, then leave to drip-dry it without wiping it. b) Install the probe into the probe holder.
  • Page 23: Automatic Test Of The Electronics Unit And The Cell

    3.4.20. Automatic test of the electronics unit and the cell This function is for use by professionals, for maintenance operations on the equipment. Menu Navigation (Wait a few seconds) Press and hold. Currents and voltages supplying the cell, on each direction of polarity inversion (values for illustrative purposes only).
  • Page 24: Alarms

    3.5. Alarms Any alarm that is activated : - appears immediately on the screen. - dismissed manually with the N button (short or long press, depending on the alarm). - can be disabled (except « »), by deactivating the sensor associated with the detected fault («...
  • Page 25: Guarantee

    4. GUARANTEE Before contacting your dealer, please have the following to hand : - your purchase invoice. - the serial no. of the electronics unit. - the installation date of the equipment. - the parameters of your pool (salinity, pH, chlorine levels, water temperature, stabilizer level, pool volume, daily filtration time, etc.). Every effort and all our technical experience has gone into designing this equipment.