ComAp InteliNano MRS 3 Operator's Manual

ComAp InteliNano MRS 3 Operator's Manual

Single small gen-set controller
Hide thumbs Also See for InteliNano MRS 3:

Advertisement

NT
InteliNano
Single small gen-set controller
Single small gen-set controller for prime-power applications
T
ABLE OF CONTENTS
1
Operator Interface ......................................................................................................................... 2
2
Display Screens Structure ............................................................................................................. 4
2.1
Main screens structure (CT not connected) ............................................................................. 4
2.2
Main screens structure (CT connected) ................................................................................... 5
3
Alarms, Events and History ........................................................................................................... 7
3.1
Events ...................................................................................................................................... 8
3.2
Warnings .................................................................................................................................. 8
3.3
Shutdowns ............................................................................................................................... 9
3.4
ECU Messages ...................................................................................................................... 10
4
Start and Stop engine.................................................................................................................. 11
4.1
MANUAL mode ...................................................................................................................... 11
4.2
AUTO mode ........................................................................................................................... 11
MRS 3
U Uranie 1612/14a, Prague 7, Czech Republic
E-mail: info@comap-control.com, www.comap-control.com
Operator Guide
Copyright © 2017 ComAp a.s.
ComAp, a.s.
Tel: +420 246 012 111

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the InteliNano MRS 3 and is the answer not in the manual?

Questions and answers

Summary of Contents for ComAp InteliNano MRS 3

  • Page 1: Table Of Contents

    Shutdowns ..........................9 ECU Messages ........................10 Start and Stop engine........................11 MANUAL mode ........................11 AUTO mode ........................... 11 Copyright © 2017 ComAp a.s. ComAp, a.s. U Uranie 1612/14a, Prague 7, Czech Republic Tel: +420 246 012 111 E-mail: info@comap-control.com, www.comap-control.com...
  • Page 2: Operator Interface

    Up (▲) button for move up or value increasing. Down (▼) button for move down or value decreasing. MRS 3 Operator Guide, ©ComAp – July 2017 InteliNano...
  • Page 3 Alarm red LED. The LED will blink when there is one or more active warning or active shutdown alarm. The LED is on when the active shutdown alarm is confirmed and the engine can’t be started. Graphic B/W display, 128x64 pixels MRS 3 Operator Guide, ©ComAp – July 2017 InteliNano...
  • Page 4: Display Screens Structure

    Second screen contains detailed voltage and frequency information. • Third screen shows the senders information – oil pressure; coolant temperature; fuel level and battery voltage. • Fourth screen shows latest alarms or events. MRS 3 Operator Guide, ©ComAp – July 2017 InteliNano...
  • Page 5: Main Screens Structure (Ct Connected)

    2.2 Main screens structure (CT connected) Figure 2.2 MRS 3 Operator Guide, ©ComAp – July 2017 InteliNano...
  • Page 6 Fifth screen shows senders information – oil pressure; coolant temperature; fuel level and battery voltage. • Sixth screen shows energy counters (real and reactive) and also running hours counter. • Last screen shows latest alarms or events. MRS 3 Operator Guide, ©ComAp – July 2017 InteliNano...
  • Page 7: Alarms, Events And History

    To view further history records you have to wait 3 seconds till down arrow stops blink, then press button (see Figure 3.2). For alarm (shutdown) confirmation press STOP button. Figure 3.1 MRS 3 Operator Guide, ©ComAp – July 2017 InteliNano...
  • Page 8: Events

    Warning symbol will blink in the upper-right corner of the LCD and the proper warning symbol will be displayed in the history with running hours stamp. Active warning can’t be confirmed. Figure 3.4 active warning – Low Battery MRS 3 Operator Guide, ©ComAp – July 2017 InteliNano...
  • Page 9: Shutdowns

    LCD, and proper warning symbol is displayed in history with running hours stamp. See Figure 3.8. For shutdown alarm confirmation press STOP button. Figure 3.8 inactive unconfirmed shutdown – Emergency Stop MRS 3 Operator Guide, ©ComAp – July 2017 InteliNano...
  • Page 10: Ecu Messages

    SAE HS-1939 Publication • Or refer to corresponding engine manufacturer’s ECU error codes list. Complete list of text diagnostic messages for each ECU can be found in ComAp Electronic Engines Support manual. MRS 3 Operator Guide, ©ComAp – July 2017...
  • Page 11: Start And Stop Engine

    The engine in AUTO mode can’t be stopped by pressing STOP button. Engine can be started or stopped via binary inputs I02 Remote Start/Stop I03 Remote Start And Load. For more details see InteliNano MRS 3 Reference Guide. MRS 3 Operator Guide, ©ComAp – July 2017 InteliNano...