  • Page 1 Window Type Air Conditioner Thank you for choosing our product. For proper operation, please read and keep this manual carefully. If you have lost the Owner’s Manual, please contact the local agent or visit www.gree.com or sent email to global@gree.com.cn for electronic version.
  • Page 2 GJC10BR-A3NRND2A GJC10BR-A3NRNC5A GJC12BR-A3NRND2A GJC12BR-A3NRNC5A...
  • Page 3: Table Of Contents

    Contents Operation and Maintenance Installation Operation Notices Installation Notice Safety Precautions......1 Installation and Maintenance..17 Precautions........4 Preparation before installation..19 Parts Name ........5 Window Types and Requirements...20 Operation Guide Installation Function and Control.......6 e l l . . . Installation procedure....21 Instruction for fan direction Sponge Sticking Method adjusting........12 and Procedures......24...
  • Page 4 This appliance is not intended for use by persons (including children) with reduc- ed physical, sensory or mental capabilities or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the ap- pliance by a person responsible for their safety. Children should be supervised to ensure they are away from the appliance.
  • Page 5 Indicates a hazardous situation that, if not avoided, will DANGER result in death or serious injury. Indicates a hazardous situation that, if not avoided, could WARNING result in death or serious injury. Indicates a hazardous situation that, if not avoided, may CAUTION result in minor or moderate injury.
  • Page 6: Safety Precautions

    Safety Precautions CAUTION When the air filter is to be Do not clean the air conditioner Ventilate the room well when used removed, do not touch the metal with water. together with a stove, etc. parts ofthe unit. It may cause an injury. Water may enter the unit and degrade An oxygen shortage may occur.
  • Page 7 Safety Precautions CAUTION “ ” Operation of Current Device NOTICE Please contact Customer Service. with a new cord - please contact Customer Service.
  • Page 8: Precautions

    Precautions WARNING ● This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
  • Page 9: Parts Name

    Parts Name Control Air outlet frame panel Fan direction adjusting rod Air-in panel Power cord...
  • Page 10: Function And Control

    Function and Control ● After putting through the power, air conditioner will give out a sound and indic- ators on control panel will be on. After that, you operate the air conditioner through remote controller or control panel. Light indicates the unit is in the temperature or delay time Set mode.
  • Page 11 Power button Press this button can turn on or turn of f air conditioner. NOTE:Press this button to turn on air conditioner, the unit will operate in Energy Save mode; if the unit is energized after power failure, the unit will still operate according to the status before power failure.
  • Page 12 Filter check button After fan rotates for 250h totally, lamp of cleaning filter is on to remind customer clean it. Note: When user cleaned the filter, press Filter check button to clear the opera- tion time. Meanwhile, the warning indicator will turn off. △...
  • Page 13 Introduction of remote controller Note: This is a general use remote controller, it could be used for the air conditioners with multifunction; For some function, which the model dosen’t have, if press the corresponding button on the remote controller that the unit will keep the original running status.
  • Page 14 - / + button ● Pressing + or - button once will increase or decrease set temperature by 1°F(°C). Hold + or - button for 2s, set temperature on remote controller will change quickly. Release the button after your required set temperature is reached. ●...
  • Page 15 Replacement of Batteries in Remote Controller 1. Press the mark “ ” on back cover of batteries box cover for remote controller with fingers as shown in the fig, and then remove the batteries box cover along the arrow direction. Battery 2.
  • Page 16: Instruction For Fan Direction Adjusting

    Instruction for fan direction adjusting ● You can adjust the fan direction adjusting rod to select left&right air outlet dire- ction according to your requirement. Fan direction adjusting rod ● You can adjust the air outlet frame to select up&down air outlet direction acc- ording to your requirement.
  • Page 17: Clean And Maintenance

    Clean and Maintenance WARNING ■ Turn off the air conditioner and disconnect the power before cleaning the air conditioner to avoid electric shock. ■ Do not wash the air conditioner with water to avoid electric shock. ■ Do not use volatile liquid to clean the air conditioner. 1.
  • Page 18: Malfunction Analysis

    Malfunction analysis General phenomenon analysis Please check below items before asking for maintenance. If the problem still can't be solved, please contact dealer or professional person. Phenomenon Troubleshooting Solution ● Power failure? ● Wait after power recovery. ● Is plug loose? ●...
  • Page 19 ● Whether air outlet or air inlet is ● Eliminate the obstacles. blocked? ● Under heating mode, whether ● The unit will stop blowing fan indoor temperature is reached No fan blowed after reaching to set temperature. to set temperature? out from air conditioner ●...
  • Page 20 Note: EP malfunction code is only applicable for cooling only unit. F1/F2/F4/FJ malfunction codes are only applicable for electric heating model. WARNING ● If there's below phenomenon, please turn off the air conditioner and disconnect the power immediately. After that, please contact dealer at once. →Power cord is overheating or damaged.
  • Page 21: Installation And Maintenance

    Installation and Maintenance Warning ● Observe all governing codes and ordinances. ● Do not use damaged or non-standard power cord. ● Be caution during installation and maintenance. Prohibit incorrect operation to prevent electric shock, casualty and other accidents. Selection of Installation Location Basic requirement Installing the unit in the following places may cause malfunction.
  • Page 22 Requirements for Electric Connection Safety precaution 1. Must follow the electric safety regulations when installing the unit. 2. According to the local safety regulations, use qualified power supply circuit and air switch. 3. Make sure the power supply matches with the requirement of air conditioner. Unstable power supply or incorrect wiring may result in electric shock,fire hazard or malfunction.
  • Page 23: Preparation Before Installation

    Preparation before installation Phillips screwdriver Screwdriver Level bar Scissors Pencil Measuring tape Window type unit Flexible screen Sealing strip ( with adhesive)(2) Upper guide rail Sealing strip ( without adhesive) Sponge R1 Sealing sponge Type A Type B Sealing strip ( with adhesive)(2) of flexible screen(2) screws(4) screws(6)
  • Page 24: Window Types And Requirements

    Window types and requirements Note: ● The description for below installation is for the standard window. If it’s other types of window, you may need to adjust the window. ● If you need to install the air conditioner at the small window, you may not need to use the flexible screen sub-assy.
  • Page 25: Installation Procedure

    Installation procedure Step 1: Install upper guide rail 1. Tear off the paster at back side of sponge, and then align it at the bottom edge of upper guide rail to stick the sponge at the bottom of upper guide rail.
  • Page 26 upper guide rail lower guide rails Step 3: Stick sealing strip Cut the sealing strip into proper length. Tear off the paster and then stick the sealing strip at the lower part of the window frame. Sealing strip ( with adhesive) Step 4: Put the air conditioner 1.
  • Page 27 Window frame windowsill Step 5: Plastic window Wooden window Step 6: Plug sealing strip Cut the sealing strip into the length same to the width of window. Plug the sealing strip between glasses and window to prevent rain and insects getting into the room. Note: If sealing strip is not proper to your window, you can select other proper materials to replace it.
  • Page 28: Sponge Sticking Method And Procedures

    Sponge Sticking Method and Procedures 1. Install flexible screen sub-assy. After finishing installation, measure the width L between outer case of air conditioner and window frame. 2. Take out R1 sponge from the package. Cut off the sponge in rectangular shape with scissors.
  • Page 29 GREE ELECTRIC APPLIANCES, INC. OF ZHUHAI Add: West Jinji Rd, Qianshan, Zhuhai, Guangdong, China, 519070 Tel: (+86-756) 8522218 Fax: (+86-756) 8669426 E-mail: gree@gree.com.cn www.gree.com 66160000534...