Advertisement

Quick Links

Change for life
Owner's Manual
Original Instructions
Window Type Air Conditioner
Thank you for choosing our product.
Please read this Owner's Manual carefully before operation and
retain it for future reference.
If you have lost the Owner's Manual, please contact the local agent
or visit www.gree.com or send an email to global@cn.gree.com for
the electronic version.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GJC12AF-E3DRNG2A and is the answer not in the manual?

Questions and answers

Summary of Contents for Gree GJC12AF-E3DRNG2A

  • Page 1 Thank you for choosing our product. Please read this Owner’s Manual carefully before operation and retain it for future reference. If you have lost the Owner’s Manual, please contact the local agent or visit www.gree.com or send an email to global@cn.gree.com for the electronic version.
  • Page 2 GJC12AF-E3DRNG2A GJC18AH-E3DRNG1A GJC24AH-E3DRNG1A...
  • Page 3: Table Of Contents

    CONTENTS Thank you for choosing air conditioner. Our design is based on the best efficiency and the lowest noise operation and it can keep the room comfortable. Please read this operating manual carefully before operating the unit and keep it for consultation. Structure mechanism and Installation Precautions Function...
  • Page 4 Explanation of Symbols Indicates a hazardous situation that, if not avoided, will DANGER result in death or serious injury. Indicates a hazardous situation that, if not avoided, could WARNING result in death or serious injury. Indicates a hazardous situation that, if not avoided, may CAUTION result in minor or moderate injury.
  • Page 5: Precautions

    Precautions Warning Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. The air conditioner should be installed in accordance with national wiring regulations. Air Conditioner should be properly grounded. Incorrect grounding may cause electric shock.
  • Page 6: Function

    Function Introduction Autumn Window type room air conditioners can regulate the room Spring Summer Winter Room temperature and dry the room. It is convenient for your work,study temp. and life. It can be widely used in residence, shop, hotel, office, library and laboratory, and so on.
  • Page 7: Operating Condition

    Operating Condition Please operate air conditioner in the correct conditions as following. DRY mode operation COOL mode operation Outdoor temperature should be in range of 18 Outdoor temperature should be in range of 18 to 43 to 43 , otherwise it is possible for air conditioner otherwise it is possible for air conditioner to breakdown.
  • Page 8: Installation

    Installation Installation precaution: Window type air conditioner is so valuable and the improper installa- tion of it will cause a lot of damage! Please associate the profes- sional technician to install the unit and don’t install it by yourself. Otherwise, we are not responsible for the damage like this. Location: The condensation water must be drained away conveniently.
  • Page 9 Installation procedure: Remove the sticker from the front panel. Put the unit into the installation hole. When installing the unit, it should be slante d Wall down to the back to avoid the enlargement of Sunshade board noise or vibration. (Slant between 6-10mm.) Shown at right figure.) The installation place should be strong enoug h Rubber plate...
  • Page 10 Drain water for one style: To get the maximum cooling efficiency, the air conditioner is designed to splash the condensate on the condenser coil. If the splashing sound annoys you, you can provide an outside drain by using the following procedure, which may however cause a small loss of performance.
  • Page 11: Notes For Installation

    Notes for installation Remove Before removing air conditioner to the other place, you should contact the seller firstly. Then it must be done under the direction of the professional technician. In addition, the charge of this must be paid. Noise Install in a location where is firm enough to avoid the enlargement of noise and vibration.
  • Page 12: Part Identification

    Part identification Panel outlook picture, just for reference, please take the real unit as standard. Cabinet Air filter (behind the front intake Air inlet grille) louver Front intake Front grille grille Remote control panel Air direction adjustment (Airflow direction adjustment up and down) The vertical airflow direction vane is controlled by positioning the vane to discharge the air upwards, downwards or straight out.
  • Page 13: Remote Control Operation Procedure

    Remote control operation procedure Note: This is a general use remote controller, it could be used for the air conditioners with multifunction; For some function, which the model doesn’t have, if press the corresponding button on the remote controller that the unit will keep the original running status.
  • Page 14 ● Dry: Under this mode, the unit runs in low fan speed for dehumidification and the corresponding indicator is on; under dry mode, the fan speed cannot be adjusted. ● Fan Only: Under this mode, air conditioner will not cool or heat, only blow wind.
  • Page 15 Timer button Under ON status, press this button to set timer OFF; Under OFF status, press this button to set timer ON. Press this button once and the characters of HOUR ON (OFF) will flash to be displayed. Meanwhile, press “+” button or “-” button to adjust timer setting (time will change quickly if holding “+”...
  • Page 16 Replacement of batteries in remote controller 1. Press the back side of remote controller marked signal sender battery the cover of battery box along the arrow direction. reinstall 2. Replace two 7# (AAA 1.5V) dry batteries, and make sure the position of "+" polar and "-" polar remove are correct.
  • Page 17: Remote Control Panel

    Remote control panel Note: If wireless remote controller is lost, you can use the remote control panel and operate manually. For heating model: ON/OFF BUTTON Operation starts when pres- sing this button, and stops when pressing this button again. SWING BUTTON Activate the automatic air For cooling only model: swing function.
  • Page 18 FILTER BUTTON This feature is a reminder to clean the Air Filter (See Care and Cleaning) for more efficient operation and cooling. The LED (light) will illuminate after 250 hours of operation. To reset after cleaning the filter, press the "Check Filter" button and the light will go off.
  • Page 19: Operation Tips

    Operation Tips Operation for comfort and economy Do not overcool the room Keep blind or curtains closed . Keep the room temp. uniform. temperature. This is not good Do not let sunshine enter the Adjust the vertical and horizon- for health and wastes electricity. room directly when the air con- tal airflow direction to ensure a ditioner is in operation.
  • Page 20: Caution

    Caution Operations for safety and health 1) The plug must be accessible after the appliance is positioned. 2) Do not use this appliance in the laundry. 3) If the power cord is damaged, it must be replaced by the manufacture or its service agent in avoid of hazard. Do not pull out the power cord.
  • Page 21: Care And Maintenance

    Care and maintenance Always turn off the air conditioner and main power supply before cleaning to ensure safety. Cleaning unit 1. Cut power off before cleaning. Air filter The air filter behind the intake grille should be washed at Plug out only after least once every two weeks or as often as it needs cleaning.
  • Page 22: Troubleshooting Guide

    Troubleshooting guide Please check the following items before asking for repair,it saves your time and money. Fault phenomenon Trouble-shooting Is there a power failure? Is the plug out? Air conditioner does not Is power fuse or switch off ? operate at all. Whether the voltage is too high or too low? Is air inlet or outlet locking? Is there any other heat/cool source in room?
  • Page 23: After Service

    Malfunction code Solution Please contact professional person to deal with it. Please contact professional person to deal with it. Please contact professional person to deal with it. Please contact professional person to deal with it. Please contact professional person to deal with it. Please contact professional person to deal with it.
  • Page 24 GREE ELECTRIC APPLIANCES, INC. OF ZHUHAI Add: West Jinji Rd, Qianshan, Zhuhai, Guangdong, China, 519070 Tel: (+86-756) 8522218 Fax: (+86-756) 8669426 E-mail: global@cn.gree.com Web: www.gree.com 600005063358...

This manual is also suitable for:

Gjc18ah-e3drng1aGjc24ah-e3drng1a

Table of Contents