Table 2: Recommended Wire Sizes For The Excel1 24V - Bergey Tilt Tower Installation Manual

Table of Contents

Advertisement

Table 2: Recommended Wire Sizes for the EXCEL1 24V

MM^2
10
16
25
30
35
50
55
70
95
120
NOTE: These wire sizes have been engineered to provide optimum rotor loading
for the BWC EXCEL1/24 wind turbine. Deviation from these recommen-
dations can result in decreased performance from your machine and / or
unnecessary additional wire-run costs. It may also cause the incidence
of nuisance breaker tripping. The use of a wire gage two sizes larger
than the recommended size is acceptable and is recommended if alumi-
num wire is used.
Turbine Installation
The fasteners on the EXCEL1 are all metric.
Tools Required:
17 mm box end wrench
17 mm socket and 12" ratchet drive
8 mm socket or wrench
pliers
crimpers for wiring terminals (U-shaped crimp preferred over straight crimp)
thread locking compound (like Locktite 242)
tape measure, 12'
torque wrench, set to 45 ft-lbs
Procedure:
Step 1:
Place the powerhead of the wind turbine near the top end of the tower.
WIRE SIZE
AWG
8 AWG
6 AWG
4 AWG
3 AWG
2 AWG
1 AWG
1/0 AWG
2/0 AWG
3/0 AWG
4/0 AWG
DISTANCE FROM TURBINE
TO POWERCENTER
METERS
FEET
0 - 35
0 - 116
36 - 56
117 - 183
57 - 89
184 - 292
90 - 112
293 - 368
113 - 141
369 - 464
142 - 178
465 - 585
179 - 225
586 - 739
226 - 287
740 - 940
288 - 361
941 - 1185
362 - 455
1186 - 1494
24