Hunter Hydrawise PRO-C Software/App Owner's Manual page 10

Irrigation controllers
Hide thumbs Also See for Hydrawise PRO-C:
Table of Contents

Advertisement

Below is a chart indicating the maximum wire run between the controller and the Hunter AC solenoid
valves.
Valve Wire Sizing (Feet)
Ground
Control Wire
18
18
850
16
1040
14
1210
12
1350
10
1460
8
1540
6
1590
Notes:
Maximum one-way distance in feet between controller and valve heavy-duty solenoid: 24 VAC, 350
mA inrush current, 190 mA holding current, 60 Hz; 370 mA inrush current, 210 mA holding current,
50 Hz
Valve Wire Sizing (Metric)
Ground
Control Wire
0.5
0.5
140
1.0
190
1.5
208
235
2.5
4.0
250
260
6.0
Notes:
Maximum one-way distance in meters between controller and valve Heavy-duty solenoid: 24 VAC,
350 mA inrush current, 190 mA holding current, 60 Hz; 370 mA inrush current, 210 mA holding
current, 50 Hz
16
14
1040
1210
1340
1650
1650
2150
1920
2630
2150
3080
2330
3450
2440
3700
1
1.5
190
210
290
335
335
397
415
515
465
595
495
647
Copyright 2021 Hunter Industries. All Rights Reserved.
12
10
1350
1460
1920
2150
2630
3080
3390
4170
4170
5400
4880
6670
54000
7690
2.5
235
415
515
730
900
1030
8
6
1540
1590
2330
2440
3450
3700
4880
5400
6670
7650
8700
10530
10530
13330
4
6
250
260
465
495
595
647
900
1030
1175
1405
1405
1745
10