Technical Data; Mpp 1500D/E - Siemens SINUMERIK MPP 1500D Equipment Manual

Machine push button panel
Table of Contents

Advertisement

Technical data

8.1

MPP 1500D/E

Safety
Protective class according to EN 50178
Degree of protection according to EN 60529
Approvals
Electrical data
Overvoltage category
Power supply
Power consumption, typ.
(without external illuminated customer keys)
Power consumption, max.
(incl. external illuminated customer keys and hand‐
held unit)
Mechanical data
Dimensions of the MPP 1500D
Dimensions W x H (mm)
Mounting depth
2)
Dimensions of the MPP 1500E
Dimensions W x H (mm)
Mounting depth
2)
Weight (kg)
Max. vertical mounting position
Tightening torques, max.
Climatic ambient conditions
Cooling
Condensation, splash water and ice formation
Supply air
Max. installation altitude (use and operation)
Machine Push Button Panel: MPP 1500D / MPP 1500E
Equipment Manual, 04/2021, A5E50753610B AA
Secondary circuit supplied from primary circuits up to Cat. III, 300 V AC
24 V DC (20.4 V ... 28.8 V)
Device
Handwheels
Total
Tension jacks: 0.4 Nm
M3 standard: 0.8 Nm
M3 weld studs/sleeves: 0.5 Nm
M4 standard: 1.8 Nm
M4 weld studs/sleeves: 1 Nm
M5 standard: 3 ...6 Nm
M5 weld studs/sleeves: 1.5 Nm (ground: 3 Nm, hold lower nut in place)
Through natural convection
Without aggressive gases, dusts and oils
Up to 1000 m without derating
From 1000 m to 4000 m with linear ambient temperature derating,
III; PELV
Front: IP54
Rear: IP00
CE / EAC
10 W
2 x 0.5 W
11.8 W
60 W
416.5 x 155
80 mm
398 x 165
80 mm
approx. 2.5
≤ 60°
Not permitted
-0.5 K per 100 m
8
1)
53

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents