Mounting cutout for the MPP 1500E
Figure 5-2
Mounting cutout for the MPP 1500E
Mount the MPP 1500E using 8 tension jacks with a tightening torque of 0.4 Newton meters at
the rear of the control panel. The tension jacks are included in the scope of delivery. The panel
thickness must be 1.5 to 6 millimeters (steel) and 2 to 6 millimeters (aluminum).
Note
Maintain the minimum clearance
The clearance to the adjacent device must be at least 10 millimeters right around the cutout
dimension.
Mounting position
The mounting position is max. 60° to the vertical. For mounting positions greater than 60°, a fan
must also be installed to keep the ambient temperature of the machine control panel constantly
below 55 °C.
See also
View (Page 28)
Pin assignment of the interfaces (Page 36)
Machine Push Button Panel: MPP 1500D / MPP 1500E
Equipment Manual, 04/2021, A5E50753610B AA
Mounting