Advertisement

Quick Links

System User Guide
Revision 1.1
NaviVision
(Hardware Package to Upgrade
Siemens C-Arm)
Version 1.0
Copyright 2006, BrainLAB AG Germany. All rights reserved.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the NaviVision and is the answer not in the manual?

Questions and answers

Summary of Contents for Brainlab NaviVision

  • Page 1 System User Guide Revision 1.1 NaviVision (Hardware Package to Upgrade Siemens C-Arm) Version 1.0 Copyright 2006, BrainLAB AG Germany. All rights reserved.
  • Page 3: Table Of Contents

    ..........54 System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 4 Turning on NaviVision (On/Stand By) ........
  • Page 5: Preface

    BrainLAB AG - Ammerthalstr. 8 - 85551 Heimstetten - Germany New address from July 1, 2006: BrainLAB AG - Kapellenstr. 12 - 85622 Feldkirchen - Germany System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 6 Not tested for ingress of water per IEC 529. Serial number of instrumentation: XXXX-YY-XX-XXXX-X Serial number of navigation stations: YY-XXX-XXXXX YY specifies the manufacturing year of the device System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 7: Symbols Used In This Manual

    Such problems include device malfunctions, device failure, damage to the device or damage to property. Helpful Hints The light bulb symbol is used to indicate additional explanatory information. System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 8: Important

    U. S. federal law restricts the sale of this product by or on the order of a physi- cian. System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 9: Introduction

    ARCADIS Varic, Orbic or Orbic 3D systems. • Upgraded system refers to the ARCADIS Varic, Orbic or Orbic 3D systems with the integrated NaviVision system. System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 10 System Information System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 11: Navivision System

    BrainLAB navigation system for the Siemens ARCADIS Varic, Orbic and Orbic 3D C-arms. Figure 1: NaviVision System (from left to right): Siemens ARCADIS Orbic C-arm (Example) and Patient Table with NaviVision Monitor Kit Attached, Mobile Camera Stand with NaviVision Camera Kit, ARCADIS Monitor...
  • Page 12: How To Use

    NaviVision system should only be used in hospitals. Unplug the ARCADIS system from the wall outlet and contact BrainLAB Support if any of the following conditions are observed: • The cable or plug is damaged or frayed.
  • Page 13 NaviVision may not be used for patient treatment before the acceptance test has been successfully performed and the acceptance protocol has been signed. System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 14: Setup Overview

    (page 63). The software loads available from Siemens), turn on the NaviVision automatically. For placement of the C-arm and trolley, refer to the ARCADIS user manual avail- able from Siemens. System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 15: Monitor

    Figure 3: NaviVision Monitor Make sure to arrange the monitor cable in such way that the user does not trip over it. System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 16: The Monitor Arm

    A height adjustment module which is attached to the curved tube and used to adjust the height of the monitor. Always hold the curved tube by the plastic handle (3). System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 17: Assembling The Monitor Arm Components

    Do not use the curved tube if cracks are visible along the welding seams. In this case, cleaning, disinfection and sterilization cannot be guaranteed. System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 18 ) into the head of the curved tube ( Figure 5: Insert Spring 2. Insert the bolt ( ) into the head of the curved tube. Figure 6: Insert Bolt System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 19 4. Insert the slider bar ( ) into the opening on the side of the head. Figure 8: Insert Bar System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 20 1. Insert the nut ( ) of the lever assembly ( ) into the lever ( Figure 10: Insert Nut of Lever Assembly System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 21 3. Insert the thumb screw into the lever assembly (left image in Figure 12) and turn the thumb screw clockwise (right image in Figure 12). Figure 12: Insert Thumb Screw into Lever Assembly and Turn Lever Clockwise System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 22 5. Turn the inner ( ) and outer tubes upside down, and carefully slide the inner tube into the outer tube. Figure 14: Slide Inner Tube into Outer Tube System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 23 If there are visible cracks, pieces broken off or scratches more than 1mm deep, the clamp is not acceptable for safe operation. System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 24: Attaching The Monitor To The Navivision System

    1. Open the unsterile clamp ( ) by turning the clamp screw in a counter-clockwise direction. Figure 15: Open the Clamp System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 25 Make sure that the clamp is securely attached to the rail with both jaws enclosing the side rail before using the monitor arm. System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 26 ) underneath the drape and insert the tube into the bottom of the clamp at a 90° angle to the table rail. Figure 19: Insert the Curved Tube into the Clamp System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 27 Do not use a tool on the clamp screw. A high amount of force on the tube may result in permanent damage to the component or lead to failure of the height ad- justment. System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 28 This component is used to adjust the height of the monitor arm. Figure 21: Insert the Height Adjustment Module 8. Open the lever ( ) on the height adjustment module. Figure 22: Open the Lever System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 29 NaviVision System 9. Lift the module to adjust it to the required height. Figure 23: Adjust the Height Module System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 30 Monitor 10. Close the lever to secure the height adjustment module in place. Figure 24: Close the Lever System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 31 Make sure that the clamp is securely fastened to the rail so that it will not slip. System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 32 Figure 26: Feed the Cable through the Drape 13. Use the tape ( ) to fix the arthroscopy drape to the connector. Figure 27: Tape the Arthroscopy Drape to the Connector System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 33 14. Remove the cap ( ) on the drape. Figure 28: Fix Drape to the Connector The draped monitor cable is shown in Figure 29: Figure 29: Monitor Cable Draped System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 34 Monitor 15. Connect the cable’s connector to the monitor sleeve ( Figure 30: Connect the Cable to the Monitor Sleeve System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 35 NaviVision System 16. The monitor can now be draped with a suitable drape (see page 44). Figure 31: Monitor Draped System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 36: Mounting The Monitor To The Arcadis Monitor Trolley

    Monitor to the 1. Open the unsterile clamp ( ) by turning the clamp screw in a counter-clockwise direc- ARCADIS Monitor tion. Trolley Figure 32: Open the Clamp System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 37 Do not use the rail on the monitor trolley with any component other than the monitor arm. Attaching components other than the monitor arm may strain the rail, causing the hardware to fall and result in user or patient injury. System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 38 Make sure that the clamp is securely attached to the rail with both jaws enclosing the side rail before using the monitor arm. System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 39 4. Insert the curved tube ( ) into the bottom of the clamp at a 90° angle to the rail. Figure 35: Insert the Curved Tube into the Clamp System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 40 Do not use a tool on the clamp screw. A high amount of force on the tube may result in permanent damage to the component or lead to failure of the height ad- justment. System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 41 ) with an integrated rotating joint into the tube. This component is used to adjust the height of the monitor arm. Figure 37: Insert the Height Adjustment Module System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 42 Monitor 7. Open the lever ( ) on the height adjustment module. Figure 38: Open the Lever System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 43 NaviVision System 8. Lift the module to adjust it to the required height. Figure 39: Adjust the Height Module System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 44 Monitor 9. Close the lever to secure the height adjustment module in place. Figure 40: Close the Lever System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 45 Otherwise, the monitor could fall resulting in patient injury or damage to the monitor. Make sure to not accidentally unlock the monitor when adjusting the height of the height adjustment module. System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 46 When moving the monitor arm, make sure not to bruise your fingers. 11. Connect the cable’s connector to the monitor sleeve ( Figure 42: Connect the Cable to the Monitor Sleeve System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 47: Selecting Functions Or Buttons

    (e.g end of a pointer). Do not touch the touchscreen using sharp tools. Use caution when tilting the monitor in order to not bruise your fingers. System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 48: Draping Using The Navivision Touch-Screen Drape

    • Put on sterile gloves. • Put the drape on the touchscreen following the instructions given on the packaging. • Verify that the drape sits firmly on the touchscreen. System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 49 Figure 45: Removing the Backing from the Drape 3. Stick the drape (where the backing was removed, see step 2) to the touchscreen. Figure 46: Attaching the Drape to the Touchscreen System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 50 Figure 47: Pulling Drape over the Touchscreen 5. Gently pull the edges of the drape down to remove any wrinkles. Figure 48: Remove Wrinkles from the Drape System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 51 NaviVision Maintaining the sterile field can only be guaranteed by using the NaviVision Touchscreen Drape provided by BrainLAB. System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 52 Check the expiration date of the touchscreen drape and do not use drape if this date is expired. If the date has expired, the touchscreen drape must be disposed System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 53: Navivision Camera Kit

    Always adjust the camera with the help of the camera handle. A smudge on the lenses can distort tracking. System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 54: Camera Field Of View

    This is especially true during registration. Positioning the Camera • Information on how to position the cameras using the Mobile Camera Stand is pro- vided on page 57. System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 55: Mobile Camera Stand

    Only the NaviVision Camera Kit should be attached to the Mobile Camera Stand System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 56: Parking Position

    • Close and lock the camera spring arm using the camera arm release button ( • Make sure that the camera interface ( ) is open. System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 57 Ensure that the camera arm is securely locked using the camera arm release button. Otherwise the camera spring arm could inadvertently jerk upwards. Properly fix the camera cable to avoid catching. System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 58: Moving The Mobile Camera Stand Into The Or

    Do not position the camera over the patient. Do not store objects under the camera stand. Lock the two wheel brakes as soon as the camera stand is in required position. System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 59: Mounting The Camera

    Do not mount the camera when the camera cable is plugged. To prevent the camera from falling, ensure that the camera interface is proper- ly locked. System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 60: Camera Cabling

    Do not activate the camera arm release button before attaching the camera. If you use a sterile camera arm handle sleeve, always remove it, grip the camera arm handle, and then release the camera spring arm. System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 61: Positioning The Camera

    When positioning the camera spring arm, you should only grip the handle or a properly attached sterile handle sleeve. Do not touch the NaviVision Camera Kit Do not leave the camera on the camera stand after surgery. System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 62: Sterilizable Camera Handle Sleeve

    ), press the release button ( Prior to clinical use verify that the sterilizable camera handle sleeve properly snapped in and cannot be removed without pressing the release button. System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 63: Dismantling The Mobile Camera Stand

    Make sure that the camera interface is open after the camera has been removed. System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 64: Connector Panel

    NaviVision workstation port (4) using a BNC cable labeled Video Monitor Connect the monitor to the plug labeled monitor using the cable provided by BrainLAB. System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 65 If you are unsure of the type of power available, consult your lo- cal power company. System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 66: Button Panel

    On/Stand By NaviVision (see page 63) a power status LED (see page 65) a service LED (see page 65) System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 67: How To Use The Button Panel

    When turning the system off, you must wait at least 15 seconds be- NaviVision fore turning it on again. Otherwise, high input current may trip the circuit breaker. System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 68: Turning Off Navivision (On/Stand By)

    Do not turn off the NaviVision system during boot up. Otherwise, configuration files and other data on the hard disk may be damaged. System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 69: Power Status Led

    NaviVision down, the Service LED will blink then and a beep will be audible. Immediately disconnect NaviVision system from the mains voltage and contact BrainLAB Support. System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 70: Transport And Storage

    • Bring the mobile camera stand into the parking position (see page 52). To prevent damage, always store the NaviVision system monitor and arm as described from page 67 for storage and transportation. System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 71: Monitor

    ) on the back of the monitor down until it is parallel to the mon- itor. Figure 62: Monitor Storage Use caution when pushing the bolt down in order to not bruise your fingers. System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 72 ( Figure 63: Monitor Storage Compartment Figure 64 shows the monitor placed in the storage compartment. Figure 64: Monitor Placed in the Storage Compartment System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 73 NaviVision system. Failure to do so could result in injury to the user or patient, and/or damage to the NaviVision system. System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 74 ) and bring the curved tube around so that it is at a 45° angle to the rail. Figure 67: Bring Curved Tube to 45°Angle to the Rail System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 75 Otherwise, you may bruise your fingers. 4. You can now remove the curved tube from the clamp. Figure 69: Removing the Curved Tube System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 76 In order to avoid the clamp components falling while removing the clamp from the rail, keep one hand beneath the clamp when turning the clamp screw counter-clockwise. System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 77: Camera

    • Make sure that the protection cover sits properly on the camera. Do not cover the camera with the protection cover when the NaviVision system is running and the camera is in use! System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 78: Technical Information

    The type plate is located on lower right side of the ARCADIS monitor trolley as indicated by the arrow in Figure 74: Figure 74: Position of the Type Plate on the ARCADIS Monitor Trolley System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 79: Compliances

    IEC 61000-4-5: 1995 + tial mode tial mode that of a typical commercial or A1: 2001 hospital environment. +/- 2 kV common +/- 2 kV common mode mode System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 80 IEC 61000-4-3:1996 + 80 kHz to 80 MHz to 800 MHz A1: 1998 + A2: 2001 2.5 GHz 0 7 P 800 MHz to 2.5 GHz System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 81 Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 10 V/m. The use of accessories or cables other than those listed above may result in in- creased emissions or decreased immunity of the system. NaviVision System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 82 IEC 60601-1-1/60601-1-2. If in doubt, consult the technical service department or your local representative. System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 83 Note 1: At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies. Note 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 84: Environmental Requirements

    243kg Modified Tempera- 15°C (59°F) to 27°C (80°F) ture Range RF Emissions Class A according to CISPR 11 System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 85: Workstation

    16.5 cm Weight 5.4 kg Power Input DC 30V/1A Host Interface RS 232 Maximum Data Rate 115 kBaud Tracking Accuracy 0.35 mm RMS (Root Mean Square) System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 86 Technical Information Mobile Camera Stand Mobile Camera Stand Weight and Dimensions Weight 33kg Footprint 0.34m² Height 2.2m System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 87: Maintenance

    We recommend that BrainLAB Support be contacted to arrange for yearly inspections or conclude a service contract. Only BrainLAB and/or authorized partners are allowed to repair the NaviVision system and the equipment. System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 88: Yearly Inspections

    BrainLAB Support to arrange an inspection. • Phone: United States and Canada (800) 597-5911 Africa, Asia, Australia, Europe +49-89-991568-44 Latin America +55 11 3256-8301 Japan 03-5733-6275 • email: worldwidesupport@brainlab.com System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 89: Further Periodical Inspections

    BrainLAB Support. Place a suitable notice such as “DO NOT USE” on the equipment to prevent it from being used inadvertently. System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 90: Safety Inspection

    1.This refers to qualifications for carrying out safety inspections on electrical medical equipment. If there is no suitably qualified person at the customer’s location, BrainLAB’s Support Specialist will carry out this inspection at cost. If you require a field service engineer, contact the BrainLAB support department.
  • Page 91: Safety Inspection Form

    0.2Ω contact to earth Reference Dimension Normal Single Fault Passed/ Conditions Conditions Not Passed Earth leakage current Impedance protective con- tact to earth Test performed (date): System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 92: Support

    War- ranties do not apply to products that have been modified or replaced without BrainLAB's written authorization. System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 93: Installation And Shipment

    BrainLAB is ready to assist you with information that will help you process claims for dam- aged or missing cartons, or for goods damaged within cartons.
  • Page 94: Return Instructions

    BrainLAB Ltd. Shibakoen 32 Mori Bldg. 4F Unit 1307, 13/F 3-4-30 Shibakoen, Lippo Sun Plaza Minato-ku, 28 Canton Road Tokyo 105-0011 Tsim Sha Tsui Japan Hong Kong System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 95 ........Monitor Arm Electromagnetic Immunity ............. Assembly ........ Environmental Requirements ....................Clamp NaviVision System ..........Components ............Storage Monitor Cable ............Draping Field of View System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 96 Shipment and Installation ....Sterilizable Handle, Mobile Camera Stand ............Storage ............Support System ............. ARCADIS ............. NaviVision ............Upgraded Technical Data ........... NaviVision Technical Specifications System User Guide Rev. 1.1, NaviVision (Hardware Package to Upgrade Siemens C-Arm) Ver. 1.0...
  • Page 98 Art-No: 60904-14EN...

Table of Contents