7. Remove the fuel nozzle.
8. Install the fuel cap on the filler port.
9. Remove the fuel grounding cable plug from pylon receptacle.
FUELING: OPTIONAL EXTERNAL FUEL GAUGE NOT
INSTALLED
1. Connect the fuel grounding cable plug to the receptacle in the pylon.
2. If the fuel nozzle is equipped with a bonding strap, touch the bonding
plug or clamp to the engine exhaust nozzle before you remove the
fuel cap.
3. Remove the fuel cap (1) from the filler port. Make sure that you do
not let the fuel cap hit the side of the fuselage (Figure 4-6).
a. Turn on the aircraft battery.
b. Select FUEL synoptic.
4. Add fuel.
CAUTION To minimize risk of fuel fill overflow and spillage,
When Fuel
Level is:
<1500 lbs
>1500 up to
2580 lbs
>2580 lbs
c. Monitor on the cockpit display.
NOTE
October 30, 2016
Honda Aircraft Company
maintain a slow, steady refuel rate as follows:
With Total
Gallons:
Less than
225 gal.
225 to 385 gal.
More than
385 gal.
The fuel quantity indication lags the actual fuel quantity
in the tank.
HJ1-29000-005-001
FOR TRAINING PURPOSES ONLY
SERVICE, HANDLING,
AND MAINTENANCE
Fueling Rate:
50 GPM
(Approx. 4 gal. every 5 sec.)
25 GPM
(Decrease fuel rate to half)
5 GPM
(Slow fuel rate significantly)
4-15