SYSTEMS
POM
DESCRIPTION
Cockpit Climate Zone
The RH BAS conditioned bleed air is ducted to pilot and co-pilot foot
warmers, aft through the center console and to the windshield and side
window defog outlets. Circulated cockpit air, via the evaporator fan,
mixes with the conditioned bleed air that is ducted to the windshield and
side window defog outlets.
The circulated cooling air exits the evaporator fan and is ducted to the
pilot overhead and panel gaspers, two cooling vents, the co-pilot
overhead and panel gaspers, the windshield and side window defog
outlets and the avionics cooling outlets.
Cabin Climate Zone
The LH BAS conditioned bleed air is ducted to three floor vents along
the LH distribution duct and two floor vents along the RH distribution
duct which are open at all times.
The circulated cooling air exits the evaporator fan and is ducted to the
passengers' overhead panel gaspers, overhead cooling flood ducts and
electronics cooling.
Indications
FCSOV status and duct temperature downstream of the TMVs can be
viewed on the ENVIRONMENTAL synoptic page. Target and actual
cabin/cockpit temperature is displayed on the synoptic page in addition
to the CDU Thermostat page. Fan speed is displayed in magenta on the
synoptic page when in Normal mode and in cyan when in Manual mode.
The target temperature value is replaced by a MANUAL icon when the
Environmental system is in Manual Control mode.
HJ1-29000-005-001
October 30, 2016
1-141
FOR TRAINING PURPOSES ONLY