CAS Messages
Message
L(R) CABIN BLEED FAIL
L(R) CABIN BLEED TEMP HIGH
ECS AIR COND FAIL
ECS GND COOLING FAN FAIL
L(R) ENG BLEED FAIL
L(R) CABIN BLEED FAULT
L(R) CABIN INFLOW OFF
ECS AIR COND FAULT
ECS TEMP CONTROL MANUAL
L(R) ENG BLEED FAULT
L(R) ENG BLEED OFF
CABIN FAN CONTROL MANUAL
CKPT FAN CONTROL MANUAL
October 30, 2016
Honda Aircraft Company
HJ1-29000-005-001
FOR TRAINING PURPOSES ONLY
Description
There has been a failure of the
cabin bleed system
The cabin bleed temperature is
above normal operating limits
when operating in Manual Mode
The Temperature Control system
has detected a failure of the
automatic system
Ground cooling fan has failed to
operate when commanded
There has been a failure of the
bleed system, or the aircraft was
powered up with a high bleed
manifold temperature
A fault in the affected cabin
bleed system detected
Associated inflow selected OFF
Either the cockpit or cabin
evaporator fan has failed
ECS manual mode has been
selected
A fault in the affected engine
bleed system detected
Bleed selected off
Cabin fan manual mode has
been selected
Cockpit fan manual mode has
been selected