FIRST RUN
NOTE
Check tightness
After installation, slowly turn on the valve on the main
water supply line.
Inspect all pipe connections involved in the installation
process for water leakage.
Make sure the circuit system is dry before it is powered.
Install power adapter
The standard power adapter is the default device providing
power to the device.
Insert the round plug at the output end of the power
adapter into the power input hole on water purifier.
Connect the power adapter to a power outlet.

Initial use and start-up

When the device is used for the first time, please check all
connecting fittings to make sure there is no water leakage.
Connect to the power supply. The device enters the
working state.

Adjust controller values

The following operations should be performed by professionals
Adjust Current Time
Adjust Regeneration Time, 2:00am by default
Adjust Regeneration Cycle
Adjust Water Usage in Regeneration Cycle
Adjust Backwash Period
Adjust Salt Absorption Regeneration Time
Adjust Wash Down Period
Adjust Water Feeding Period
Adjust Regeneration Mode, please select the Flow-delay-
based Regeneration Mode

First water running

Slowly turn on water inlet valve to the 1/4 position. Quick
operation will result in loss of filter material. The sound can
be heard because air is slowly emitted when water flows
into the valve. After the air in the composite wrapped
pressure vessel is completely evacuated and water flows
stably, fully turn on the valve.

Backwash

Rinse for 5 minutes to allow sewage water to drain from the
drain pipe.
NOTE

Precautions for use

Keep the device upward in the process of storage, transport
and installation. Do not place the device horizontally or
upside the device down.
Do not apply external force to the device. Avoid direct
sunlight and keep away from radiation sources.
Please turn off the water inlet valve when the user is
absent from home for a long time.
Please power off the device when the user is absent from
home for a long time.
Please use the device at the temperature of 1-39ºC,
because the Composite wrapped pressure vessel in the
device may be frozen and broken at the temperature below
0ºC. The filter materials in Composite wrapped pressure
vessel will be broken in a cool environment, resulting in
failure.
The automatic regeneration start time is 2:00am by default.
The effluent during regeneration is not softened. At this
moment, water use will affect the normal operation of the
device.
If power failure lasts more than 24 hours, the current time
of the controller should be adjusted again, but other
parameters stored in the controller will not be lost.
After the device is not used for a certain period,
regeneration process should be made manually before
re-use.
When water usage increases sharply (by comparing to
normal water usage) or the hardness of raw water
increases, shorten regeneration cycle and increase
regeneration frequency.