Table continued from last page
Gas
ULPG
The hotplate can be connected with rigid pipe as specified in AS/NZS 5601.1 current edition.
Fitting of appliance regulator for Natural gas or test point adaptor for LPG.
Check and set the gas pressure with appliance operating!
Connecting & testing
WARNING!
Check if connections are gastight.
Burner
Injector
burner (mm)
Simmer
0.46
Normal
0.60
Large
0.72
Wok
0.93 + 0.40
Adj. screw
Burner rate
(mm)
(MJ/h)
0.26
2.60
0.30
4.90
0.36
7.10
0.40
13.60
Installation
Gas pressure
(kPa)
2.75
23