INSTALLATION

Installation of the cooler must be done according to applicable local codes or equivalent.

Ambient Environment

Place cooler on an even surface to reduce
vibration and noise.
To transport, do not tilt the cooler beyond
a 45 degree angle.
Do not place cooler in direct sunlight or
near any heat sources.
Do not place cooler in environment
temperatures that exceed 80°F.
Do not place cooler in below normal
temperatures.
Do not place cooler in extreme humid
environments, this may cause components
to rust.

Preparation Prior to Operation

Remove all packaging materials before
using cooler. This includes: foam pedestal,
adhesive tape (used to fi x accessories) and
protective gaskets.
Inspect cooler for concealed damage.
Immediately fi le a claim with the freight
carrier if there is damage. IDW is not
responsible for damage incurred during
shipping.
Cooler must remain unplugged in an

Electrical Requirements

This model operates with a 110-120V/60Hz
power supply. Check the electrical outlet
for proper voltage.
Dedicate one outlet for the use of the
cooler.
Do not use an extension cord or any other
multiple connectors as this can lead to
compressor failure.
If the cord is damaged, it must be replaced.
6
Do not place cooler near constant running
or splattering water, this may cause
immediate damage to refrigeration system.
Must allow at least 4" between rear of
cooler and wall for proper ventilation and
heat dissipation of cooler.
Do not place furniture or other articles with
sharp edges near the cooler in order to
prevent damage to the glass door.
This cooler is for indoor use.
Place unit in it's fi nal location, making certain
there is adequate ventilation in the room.
WARNING: Warranty is void if ventilation
is insuffi cient.
upright position for 1 hour prior to use.
Clean the interior surface with a soft cloth
and lukewarm water before operation.
Ensure that drain hose or hoses are
positioned in the pan.
Remove plug and cord from inside the
lower rear of the cooler.
The unit should be placed close enough
to the electrical supply so that extension
cords are not used.
For your safety, plug the unit into a
grounded wall outlet. Please check with a
certifi ed electrician for details.
WARNING: Do not use extension cords.
WARNING: Compressor warranties are
void if compressor burns out due to low
voltage.
WARNING: Power cord ground pin must
NOT be removed!
CAUTION FLAMMABLE REFRIGERANT
DANGER – Risk Of Fire Or Explosion. Flammable Refrigerant Used. To Be Repaired
CAUTION FLAMMABLE - R600a Refrigerant
Only By Trained Service Personnel. Do Not Puncture Refrigerant Tubing.
CAUTION – Risk Of Fire Or Explosion. Flammable Refrigerant Used. Consult Repair
DANGER – Risk Of Fire Or Explosion. Flammable Refrigerant Used. To Be
Manual/Owner's Guide Before Attempting To Install or Service This Product. All Safety
Repaired By Trained Service Personnel Only. Do Not Puncture Refrigerant Tubing.
Precautions Must be Followed.
CAUTION – Risk Of Fire Or Explosion. Flammable Refrigerant Used. Consult
CAUTION – Risk Of Fire Or Explosion. Dispose Of Properly In Accordance With
Repair Manual/Owner's Guide Before Attempting To Service This Product. All
Federal Or Local Regulations. Flammable Refrigerant Used.
Safety Precautions Must be Followed.
CAUTION – Risk Of Fire Or Explosion Due To Puncture Of Refrigerant Tubing; Follow
CAUTION – Risk Of Fire Or Explosion. Dispose Of Property In Accordance With
Handling Instructions Carefully. Flammable Refrigerant Used.
Federal Or Local Regulations. Flammable Refrigerant Used.
CAREFUL - Handling, moving and operating of the refrigerator or freezer to avoid
CAUTION – Risk Of Fire Or Explosion Due To Puncture Of Refrigerant Tubing;
either damaging the refrigerant tubing, or increasing the risk of a leak.
Follow Handling Instructions Carefully. Flammable Refrigerant Used.
CAUTION - Component parts shall be replaced with like components and that
servicing shall be done by factory authorized service personnel, so as to minimize the
risk of possible ignition due to incorrect parts or improper service.

LEVELING

PRUDENCE INFLAMMABLE - R600a Réfrigérant
Set unit in its fi nal location making certain there is adequate
DANGER - Risque d'incendie ou d'explosion. Réfrigérant inflammable utilisé.
ventilation in the room.
Pour être réparé que par un personnel de maintenance qualifié. Ne pas percer
réfrigérant Tubing.
WARNING: Warranty is void if ventilation is insuffi cient.
ATTENTION - Risque d'incendie ou d'explosion. Réfrigérant inflammable utilisé.
Proper leveling of the cooler is critical to it operating
Consultez manuel / guide de l 'utilisateur de réparation avant de tenter de
correctly. Condensation removal and door operation are
réparer ce produit. Toutes les précautions de sécurité doivent être respectées.
both affected by leveling.
ATTENTION - Risque d'incendie ou d'explosion. Aliéner des biens conformé-
ment à la réglementation fédérales ou locales. Réfrigérant inflammable utilisé.
The cooler should be leveled front to back and side to side
with a level.
ATTENTION - Risque d'incendie ou une explosion due à la perforation de
tuyaux de réfrigérant; suivre les instructions de manipulation avec précaution.
Ensure the drain hose or hoses are positioned in the pan.
Réfrigérant inflammable utilisé.
Remove the plug and cord from inside the lower rear of the
cooler.
The unit should be placed close enough to the electrical
supply so that extension cords are never used.

SHELVING INSTALLATION

Securely insert shelf clips into
Shelf clips should be level so
pilasters
shelf lays fl at
Innovative DisplayWorks, Inc.
(Maximum load per shelf is
Display refrigerators can be loaded within the shelf dimensions from the front
G-26c/GCG-26c
(Maximum load per shelf is 123 lbs)
Display refrigerators can be loaded with-
in the shelf dimensions from the front
to back side. They can also be loaded
in any space from the bottom to the top
interior cabinet. Do not allow product to
block the evaporator fan cover because
the evaporator fan helps the cooler to
ventilate properly.
7
lbs/ kg)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents