SAFETY INSTRUCTIONS

1.
When using this appliance, always follow
the basic safety precautions:
2.
Read the entire User's Manual before
operating this appliance.
3.
Use this appliance only for its intended
purpose as described in this User's Manual.
4.
This cooler must be properly installed
in accordance with the installation
instructions before being used. See
grounding instructions.
5.
IDW requires that a dedicated circuit be
used for the unit. Failure to do so voids
warranty.
6.
Never unplug your cooler by pulling on the
power cord. Always grasp the plug fi rmly
and pull it straight out from the outlet.
7.
Unplug your cooler before cleaning or
making any repairs.
Note: If for any reason this product
requires service, we strongly recommend
that a certifi ed technician perform the
service.
8.
When disconnecting the power source,
wait at least 5 minutes to reconnect the
power to avoid damage to the compressor
and the cooling system.
9.
Immediately repair or replace all electrical
cords that have become frayed or
otherwise damaged. Do not use a cord that
shows cracks or abrasion damage along its
length, the plug or the connector end.
10. Do not operate or store your cooler near or
around explosive fumes, gasoline or other
fl ammable vapors and liquids.
11. Do not use fl ammable liquids to clean unit.
12. Setting the temperature control to the
0 position does not remove power to
the light circuit, perimeter heaters, or
evaporator fans.
13. Do not adjust the temperature control. The
temperature control is factory set between
levels 4 and 5 for maximum performance.
14. To avoid damage to the casters, do not
transport the cooler on rough surfaces.
8
PLEASE SAVE THESE
INSTRUCTIONS!
DANGER!
PROPER DISPOSAL OF THE
REFRIGERATOR
Pre-Caution, Non-Operating Coolers
Should Have:
1. Lid removed.
2. Baskets kept in place in order
to prevent any small child from
climbing inside cooler.
For Proper Disposal of Cooler:
Distributors/retailers need to contact
a qualifi ed service technician:
1. To recover all refrigerant from
the cooler
2. To remove the compressor
or remove the oil from the
compressor
Then the distributor/retailer can
contact their local metal recycling
center to pick up the remaining
cabinet, shelves, etc. By law, disposal
of hazardous wastes may be subject
to fi nes and imprisonment under
the provisions of the environmental
regulations. For more information
please visit: http://www.epa.gov/
osw/hazard/index.htm

INSTALLATION

Installation of the cooler must be done according to applicable local codes or equivalent.

Ambient Environment

Place cooler on an even surface to reduce
vibration and noise.
To transport, do not tilt the cooler beyond
a 45 degree angle.
Do not place cooler in direct sunlight or
near any heat sources.
Do not place cooler in environment
temperatures that exceed 80°F.
Do not place cooler in below normal
temperatures.
Do not place cooler in extreme humid
environments, this may cause components
to rust.

Preparation Prior to Operation

Remove all packaging materials before
using cooler. This includes: foam pedestal,
adhesive tape (used to fi x accessories) and
protective gaskets.
Inspect cooler for concealed damage.
Immediately fi le a claim with the freight
carrier if there is damage. IDW is not
responsible for damage incurred during
shipping.
Cooler must remain unplugged in an

Electrical Requirements

This model operates with a 110-120V/60Hz
power supply. Check the electrical outlet
for proper voltage.
Dedicate one outlet for the use of the
cooler.
Do not use an extension cord or any other
multiple connectors as this can lead to
compressor failure.
If the cord is damaged, it must be replaced.
Innovative DisplayWorks, Inc.
G-77/G-80/G-80L
Do not place cooler near constant running
or splattering water, this may cause
immediate damage to refrigeration system.
Must allow at least 4" between rear of
cooler and wall for proper ventilation and
heat dissipation of cooler.
Do not place furniture or other articles with
sharp edges near the cooler in order to
prevent damage to the glass door.
This cooler is for indoor use.
Place unit in it's fi nal location, making certain
there is adequate ventilation in the room.
WARNING: Warranty is void if ventilation
is insuffi cient.
upright position for 1 hour prior to use.
Clean the interior surface with a soft cloth
and lukewarm water before operation.
Ensure that drain hose or hoses are
positioned in the pan.
Remove plug and cord from inside the
lower rear of the cooler.
The unit should be placed close enough
to the electrical supply so that extension
cords are not used.
For your safety, plug the unit into a
grounded wall outlet. Please check with a
certifi ed electrician for details.
WARNING: Do not use extension cords.
WARNING: Compressor warranties are
void if compressor burns out due to low
voltage.
WARNING: Power cord ground pin must
NOT be removed!