2.3 Precautions for dust

About dust
- This product is for use indoors.
- -When it is used at outdoor, or at dusty places, such as railway station or close to
the traffic, the measures against dust must be considered.
Please observe the following instructions when installing.
The effect of dust
-If the anti-dust measure against dust is not considered ->
The dust will enter into the LCD panel through the gaps and will cause the distorted
image (see example below), and will break down in the end.
The dust enters into the LCD panel
Please don't set up vent, when installing the monitor on to the pole and the wall. The
dust causes the above situation by intrusion of dust to inside of the product.
Countermeasure against dust
-Create a completely sealed enclosure.
-The completely sealed enclosure can shut off dust so it is advantageous for
installation in locations under the effect of excessive amounts of dust, outdoor, and a
salt damage.
-You will need the countermeasures against thermal at the same time, such as using
the heat exchanger or the air conditioner etc.
Regular maintenance of the enclosure is required to maintain performance.
and causes the distorted image.
Copyright © All rights reserved, SHARP CORPORATION
Precautions for using anti-dust enclosure
-When using the anti-dust display(enclosure), please remove the dust with filter.
Precautions for using the filter
(1)it is possible to prolong the filter life by using two filter and
exchanging the fine screen pre-filter.
(2)it may raise the internal temperature for a monitor when using the filter, because of raising
the air resistance.
Please reduce the air resistance by increasing the area of filter, etc.
(3)when circulating air with a fan, it needs attention how to make the enclosure whether
exhaling or inhaling air from the fan.
Intake air fan:
The pressure in the enclosure is higher than out of enclosure. Therefore, dust does not break in
the housing. It is limited the size of intake vent. And it is difficult to suck in much air(when using
in dusty area).
Exhaust air fan:
The pressure in the housing is lower than out of enclosure. Therefore, dust breaks in the
housing. It has much size of intake vent. And it is easy to control the temperature(when using
in less dusty area and severe temperature requirements).
※to keep the performance, please clean the filter regularly
Air intake fan
Air exhaust fan
Confidential