2.1 Precautions for temperature ,clearance space and installation environment

Temperature conditions
- Operating temperature range
→32°F (0℃)-104°F (40℃)
※ 1
- Operating Humidity range
→20%-80%RH (No condensation)
- Temperature of LCD surface
Please follow these requirements when setting the monitor. Refer to the
measures against temperature and install the monitor in accordance with its
requirements.
※1: This range may change by installation conditions.
The thermal influence
- If the temperature is too high → Electronic component's life time will be
shortened or break down.
-If the temperature on LCD surface is too high → Monitors will break down or
uniformity issue will occur
- If the temperature is too low → Monitors will break down, will not start up or
monitor issue will occur.
Measures against temperature 1
This monitor should be used at an ambient temperature between 32°F(0 ℃)
and 104°F (40℃).
※ 1
→ Below 140°F(60℃)
Copyright © All rights reserved, SHARP CORPORATION
Measures against temperature(2)
When installing the monitor, please secure Top/ Bottom/ Left/ Right clearances
and use it within the range of ambient temperature the chart below .
*The values in the chart are when it is not in the casing.
If you install with outer casing, requirements are changed by size/location of vent hole, whether there is
a fan or not.
The effectiveness of each measure differs depending on the environment. Please
choose the best measure for respective environment as follow.
- Using a cooling fan(However please note that the temperature inside the casing is
difficult to be lowered when dust is corrected and use the filter and clean it regularly.)
- Improve the ventilation by widening its space
- Using a heat exchanger
Heat prevention unit
(Reference values)
Example of fan installation
(Apiste co.)
Confidential
9 9