baltur BT 17N Instruction Manual For Installation, Use And Maintenance page 44

Single-stage fuel oil burner
Table of Contents

Advertisement

Available languages

Available languages

ENGLISH
GRAVITY SUPPLY SYSTEM
1
2
5
IMPORTANT
For any components missing in the pipes, comply with current
regulations.
IMPORTANT
Total length of pipeline, including vertical length.
Deduct 0.25 m for each elbow or gate.
SIPHON FEED SYSTEM WITH FEED FROM THE TOP OF THE TANK
1
10
7
6
IMPORTANT
For any components missing in the pipes, comply with current
regulations.
IMPORTANT
Total length of pipeline, including vertical length.
Deduct 0.25 m for each elbow or gate.
4
9
7
6
8
3
4
9
8
3
44 / 64
0006160045_201802
1
Fuel tank.
2
Feeding pipe.
3
Mesh filter.
4
Burner.
5
Degasifier.
6
Suction pipe.
7
Burner return pipe.
8
Automatic fuel shut-off device with burner at stop.
9
One-way valve.
H
m
1
2
2,5
3
1
Fuel tank.
3
Mesh filter.
4
Burner.
6
Suction pipe.
7
Burner return pipe.
8
Automatic fuel shut-off device with burner at stop.
9
One-way valve.
10
Foot valve.
Value "P" max. 3.5 m
H
Measurement between minimum oil level and pump axis.
H
m
1
2
2,5
3
Inner pipe diameter
Ø 1"
Total length of each pipe
m
31
35
35
35
Inner pipe diameter
Ø 1"
Total length of each pipe
m
31
35
35
35

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

2008541020080010

Table of Contents