Download Print this page

Prestan Adult Manikin 2000 Series Use And Care Instruction page 5

Hide thumbs Also See for Adult Manikin 2000 Series:

Advertisement

The CPR Monitor provides feedback for both rate and depth and when connected to a smart device via
Bluetooth®, can also provide recoil, hands-off time and ventilations.
At 2" depth you will hear an audible "beep" to indicate that the recommended depth has been
reached.
The lights in the left shoulder area of the torso will light to indicate the rate and will show two green
lights when the recommended rate has been reached.
The CPR Monitor (requires two (2) 'AA' batteries; not included) is a patented feedback feature that
comes pre‐installed in the shoulder area of the PRESTAN Professional Adult Series 2000 Manikin. If you
have purchased a PRESTAN Professional Adult Manikin with or without the CPR Monitor and later
decide you want to upgrade to the Series 2000 Manikin with recoil, ventilation, hands off time, depth,
and rate of compressions – the Series 2000 Upgrade Kit may be purchased and installed separately by
contacting your PRESTAN Authorized Distributor.
To start the PRESTAN Professional Adult Series 2000 Manikin a single, one (1) second long compression
is required at which time you will hear a beep and see the LED lights illuminate according to the table
below. This will signal that the manikin is ON and ready for use.
The PRESTAN Professional Adult Series 2000 Training Manikin CPR Monitor has a unique way of
monitoring and providing CPR Feedback for both rate and depth using a series of LED lights and sounds.
Advanced CPR Feedback is provided for rate, depth, recoil, ventilation, and hands-off time through the
use of LED lights, sounds, and the PRESTAN CPR Feedback app available on both iOS and Android
devices. Operation of the LED lights and the PRESTAN CPR Feedback app can be found below and on
the following pages.
COPYRIGHT© 2021 PRESTAN PRODUCTS, LLC
CPR MONITOR GUIDE
5
12716-RevB

Advertisement

loading