Download Print this page

RESEARCH CONCEPTS RC4000 Protocol page 13

Antenna controller
Hide thumbs Also See for RC4000:

Advertisement

RC4000 Antenna Controller
Device Status Poll Command (continued)
byte 40
7 6 5 4
0 B B B $ S S S S
bytes 41-44
byte 45
7 6 5 4
0 1 0 L $ 0 C C C
Appendix REM
current track status – binary data
3 2 1 0
where 'BBB' is ...
001 – X band
010 – Ka band
011 – S band
100 – C band
101 – Ku band
111 – L band
and where 'SSSS' is ...
0000 – track mode not active
0001 – track setup submode active
0010 – track auto mode entry
0011 – step track submode active
0100 – track auto search submode active
0101 – program track submode active
0110 – track manual search submode active
1000 – track jammed error
1001 – track limit error
1010 – track drive error
1011 – track peak limit error
1100 – track geo position error
1101 – track system error track
1110 – track checksum error
AGC Level
The AGC channel voltage is represented internally by a numeric
value between 0 and 4095. This numeric value is converted to
an ASCII string. The string will be right justified and padded with
blanks (on the left).
AGC Channel The AGC channel and lock status – binary data
3 2 1 0
where 'CCC' is ...
000 – RF
001 – SS1
010 – SS2
011 – DVB
1xx – reserved
where 'L' is ...
1 – lock indicated
0 – no lock indicated
REM-13
Remote Control Option

Advertisement

loading