Download Print this page
S&P INITIA 225 Installation Manual And Switching On
S&P INITIA 225 Installation Manual And Switching On

S&P INITIA 225 Installation Manual And Switching On

Advertisement

Quick Links

INITIA 225
EN
Installation manual and switching on

Advertisement

loading
Need help?

Need help?

Do you have a question about the INITIA 225 and is the answer not in the manual?

Questions and answers

Summary of Contents for S&P INITIA 225

  • Page 1 INITIA 225 Installation manual and switching on...
  • Page 2: Table Of Contents

    Contents General information Technical information Installation Characteristics and electrical connections Verification of the INITIA Switching on the INITIA Switching on the INITIA Before undertaking any work, turn off and disconnect the machine. During normal operation, never stop the ventilation system.
  • Page 3 1.2 Warranty and Liability Warranty The INITIA 225 heat recovery system has a three year warranty from the date of purchase. This warranty includes free delivery of necessary spare parts. The warranty does not cover: Installation and removal costs Defects that, in the opinion of Soler &...
  • Page 4: General Information

    2 Technical information 2.1 General information The INITIA 225 ensures optimum ventilation of a house with a maximum energy recovery. It draws air from the rooms (bathroom(s), toilet, kitchen and wash room(s)) and supplies fresh air through the main rooms (living room, bedroom (s), office, etc ).
  • Page 5 Fresh air intake This spigot is to connect the supply duct of fresh air from outside. To prevent condensation it is recommended to use insulated ducts. Install the fresh air intake (wall or roof) a sufficient distance from any area of high pollution (trees, exhaust fumes, road, etc).
  • Page 6 2.3 Dimensional characteristics: 2.3-a Main unit: Weight: 41 Kg: 2.3-b Timer: 75x75...
  • Page 7: Installation

    3 Installation Wall mount 3.1 Vertical wall: Uninsulated Insulated duct  Insulated duct  duct  Ducts must be insulated and perfectly inserted 3.2 On the ground: It is advisable to install the INITIA in the heated area of the house. If not, it is essential to isolate the condensation drain.
  • Page 8 3.3 On level ground: Specific optional kit (foot and condensation drain) Calle Conduit non Conduit isolé Conduit isolé isolé DO NOT INSTALL THE INITIA IN A CEILING DO NOT INSTALL THE INITIA IN A CEILING • It is advisable to install the INITIA in the heated area of the house. If not, it is essential to isolate the condensation drain.
  • Page 9 SAMPLE “DISTRIBUTION” ASSEMBLY CPR or CT Kitchen BDO or BOAP BDO or TPM Bathroom installations Bathroom installations 7 spigot distribution Gable air vent D150 Lounge/living room /li i & Bedrooms PAF 150 4 or 8 spigots Roof air vent D150 distribution When using insulated flexible insulated flexible...
  • Page 10 SAMPLE “DISTRIBUTION” ASSEMBLY CT 150 CT 150 Lounge/Living room BDOP 125 Kitchen BDOP 125 BDOP D80 RD80 Bedrooms Bathrooms Bathrooms BDOP D80 RD80 Gable air vent D150 When using insulated flexible duct, it is imperative to PAF 150 correctly tense it. Roof air vent D150...
  • Page 11: Characteristics And Electrical Connections

    4 Characteristics and electrical connections Connect the supplied cable to the mains using a sealed connection box. Power distribution box Cable type H05VV-F-5G1 Lenght 1.2 m Connection box Câblage avec fonction rafraîchissement nocturne Power: Single phase 230V-50Hz Electrical protection:3A Max. Power:230 W Maximum ambient temperature:50ºC Maximum flow temperature:45ºC Do not turn on the unit the ventilation system is complete (air intake, discharge grille or roof outlet, air and extraction vents, network and filters installed)
  • Page 12: Verification Of The Initia

    5 Verification of the INITIA 5.1 etting the operating speeds. The INITIA has 3 operation speeds controlled by three adjustable potentiometers on the control unit (1). Flow rates depend on the configuration of the house, depending on the number of main rooms (living room, dining room, bedroom, office, etc) and the number and type of service rooms (bathroom, toilet, laundry, etc), and the surface area.
  • Page 13 Other countries: Réglage potentiomètres/Débits Flow  Flow  Poten.  Débit  Poten.  Poten.  rate  rate  1  For example: For example: Mini calculated flow rate = 105m3/h → Potentiometer 1 / Position 2 Max flow calculated = 180 m3/h → Potentiometer 2 / Position 3 Cool air flow (by way of example;...
  • Page 14: Switching On The Initia

    • Clogged filters alarm (3): When the filters are clogged, a red LED (4) appears to warn you to change the filters. Remove the filter covers (F1= Filter F5 on intake network or F2= Filter G4 on extraction network). Once the filters have been changed, press the icon to reset (LED goes off). •...
  • Page 16 S&P Sistemas de Ventilación S.L.U. C/ Llevant, 4 08150 Parets del Vallès (Barcelona) Tel. +34 93 571 93 00 Fax +34 93 571 93 01 www.solerpalau.com...