Notice On Maintenance - Gree FLEXX36HP230V1AO Installation & Owner's Manual

Hide thumbs Also See for FLEXX36HP230V1AO:
Table of Contents

Advertisement

DC Inverter Series for R410A Unitary Split Air Conditioner
4.3.1 Heat Exchanger of Outdoor Unit
Conduct cleaning for the heat exchanger of outdoor unit periodically, clean it
once at least in every two months. Clean the dust and sundries on the surface of the
heat exchanger with dust collector and nylon brush, if there's compressed air
source; use the compressed air to blow the dust on the surface of the heat
exchanger. Don't use tap water for cleaning.
4.3.2 Drainage Pipe
Periodically check if the drainage pipe is blocked to smooth the condensate
water.
4.3.3 Notices at the Beginning of the Using Season
(1)
Check if the air inlet/outlet of the units are blocked.
(2)
Check if the ground connection is reliable.
(3)
Check if the air filter screen is properly installed.
(4)
If starting up again after long-term shut down, preset the power switch of air
conditioner to "ON" status before 8h of operation, to preheat the crankcase
of outdoor compressor.
(5)
Check if the installation of outdoor unit is firm, if not, please contact with
Gree appointed maintenance center.
4.3.4 Maintenance at the End of the Using Season
(1)
Cut off the main power of air conditioner.
(2)
Clean the dust and sundries in outdoor unit.
(3)
If the outdoor unit is rusty, coat the rusty location with paint to prevent it from
expanding.
4.3.5 Components Replacement
Components are available in Gree agency or Gree distributors nearby.

4.4 Notice on Maintenance

4.4.1 Information on Servicing
The manual shall contain specific information for service personnel who shall
be instructed to undertake the following when servicing an appliance that employs a
flammable refrigerant.