Cylinder Filling Procedure - Paramina MISTRAL CLASSIC M6-ET User Manual

Table of Contents

Advertisement

User Manual - Mistral M6&M8 -
Cylinder filling procedure 
Make sure that filling hoses as well as threads are in perfect condition without cracks or breaks.
Filling hose connectors should be connected on the cylinder without the use of tools. Sealing is achieved with o-ring
and internal pressure.
A. Filling hose connectors used for filling cylinders up to 232 bar are divided in two categories:
Filling Connector according to DIN 200
INTERNATIONAL / ''A'' Clamp Adaptor
INTERNATIONAL
/ ''A'' Clamp Adaptor
(Only up to 232 bar)
B. For cylinders filling at 330 bar, only the use of filling connectors according to DIN 300 (different adaptor
than the one at DIN 200 bar) is allowed.
DIN 300 filling connector
(ATTENTION: longer adaptor)
(Up to 330 bar)
Use cylinders that correspond to the pressures produced by the compressor
Check the cylinder safety pressure (232 or 330 bar for example) so as to correspond to the preset final pressure of
the compressor.
Connect the cylinder, having the filling hose connector's valve and the cylinder's valve turned off, and start the
compressor by pressing the Start button.
Then, first turn on the filling hose connector's valve and then the one of the cylinder.
PARAMINA SA – Byway Evaggelistrias str. 19300 Aspropirgos, Greece, Tel: 0030 210 5575860
Fax: 0030 210 5575868, email:
04-2018 from s.n.1882761 edition
200bar Filling
service@paramina.gr
DIN 200 filling connector
(Only up to 232 bar)
All the using filling
cylinders must be in accordance
with international standards and
directives.
They must have the
corresponding mark (symbol
and technical data) at its neck
and a valid hydraulic
overpressure certificate test.
Cylinder valve has to be DIN200
(according to EN 144-2).
- website:
www.paramina-compressors.com
.
12

Hide quick links:

Advertisement

Table of Contents
loading