Troubleshooting - Paramina MISTRAL CLASSIC M6-ET User Manual

Table of Contents

Advertisement

User Manual - Mistral M6&M8 -
Trouble Shooting 
CAUTION
Before any maintenance work on the compressor, make sure there is not air inside, under pressure.
Every time you stop the compressor, ALWAYS open the manual drains so as to remove condensate.
Maintenance work on the compressor must always be done with the compressor stopped and disconnected from
the mains supply. Never forget to open the manual drains, after stopping the compressor.
Especially when you are planning to clean the solenoid valves (auto drains version), always turn off the main
electrical supply.
You must always have in mind, if you disconnect the coil of the solenoid valves, without turning off the electrical
supply, it will be destroyed immediately!!!
Trouble
Motor does not start
Decreased
performance of the
compressor
Compressor does not
attain final pressure
Interstage Safety
valves releasing
PARAMINA SA – Byway Evaggelistrias str. 19300 Aspropirgos, Greece, Tel: 0030 210 5575860
Fax: 0030 210 5575868, email:
04-2018 from s.n.1882761 edition
Cause
Electric circuitry faulty
Thermal switch enabled
1.Blocked air intake filter
st
nd
rd
2.1
stage, 2
stage or 3
are not properly closed
st
nd
rd
3.1
stage, 2
stage or 3
rings worn
4.Worn cylinders
5.Pipes leaking
6.Solenoid valves stuck open
7.Unstable power supply - voltage
8.Wrong cable diameter or long cable
9.Interstage safety valves leaking
1.Condensate drain Valve and / or fittings
leaking
2.Premature opening of final safety valve
3. Excessive piston clearance
4. Final Safety valve's safety lock opens
prematurely
5.Interstage safety valves leaking
6.Final stage piston rings worn
st
1.If the 1
stage safety valve is released,
nd
the 2
stage valves do not close properly
service@paramina.gr
Check power supply fuses or/and
compressor fuses, terminal
connections, wire leads.
1.Clean - Replace
stage valves,
2.Check the intermediate pressures
stage Piston
3.Replace
4.Replace
5.Tighten and reseal
6.Clean - Replace
7. Check power supply fuse box
8.Check - Replace
9.Check - Replace
1.Tighten and reseal
2.Clean final safety valve and readjust
3. Replace and regulate again
4. Check the intermediate pressures,
regulate or replace valves
5.Check - Replace
9.Check - Replace
1.Check – replace valves
- website:
www.paramina-compressors.com
Remedy
.
28

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents