Make sure that filling hoses as well as threads are in perfect condition without cracks or breaks.
Filling hose connectors should be connected on the cylinder without the use of tools. Sealing is achieved
with o-ring and internal pressure. The filling hose connectors used for filling cylinders up to 220 bar are
divided in two categories:
Filling hose connector according to DIN 477
INTERNATIONAL / ''A'' Clamp Adaptor
For pressures at 330 bar, only the use of filling hose connector according to DIN 477 (with different thread
than the one at 220 bar) is allowed. Use of any kind of adaptor is strictly forbidden.
INTERNATIONAL / ''A'' Clamp Adaptor
(Only for 220 bar)
DIN filling hose connector for 330 bar
(ATTENTION: longer thread)
Use cylinders that correspond to the pressures produced by the compressor
Check the cylinder safety pressure (220 or 330 bar) so as to correspond to the preset final pressure of the
compressor.
Connect the cylinder, having the filling hose connector's valve and the cylinder's valve turned off, and start
the compressor (see page 8).
Then, first turn on the filling hose connector's valve and then the one of the cylinder.
PARAMINA SA – Byway Evaggelistrias str. 19300 Aspropirgos, Greece, Tel: 0030 210 5575860-1
Fax: 0030 210 5575868, email:
12/2013 edition
service@paramina.gr
- website:
www.paramina-compressors.com
DIN filling hose connector for 220 bar
200 bar filling
.
11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents