User Manual - Mistral M6&M8 -
Replacement of active carbon - molecular sieve cartridge / coalescing cartridge
PARAMINA compressors operate at environmental temperatures from -5
temperatures could cause changes in the quality of breathing air; lower temperatures may cause a
malfunction.
CAUTION: Before any interference in the filter's housing, make sure there is not inside air under
pressure.
Maintenance work on the compressor must always be done with the compressor stopped and
disconnected from the mains supply.
Filter's housing lifetime is 20 years. Hydraulic Overpressure test, every 5 years.
Option 1 (standard equipment till s.n.1882866 - Ø80x345 BA Filter):
1. Unscrew the filter housing by hand and remove it from its base.
2. Unscrew the A.C.-M.S. cartridge from the cartridge connector. Place and hold a wrench on the cartridge
connector while unscrewing the cartridge.
3. Lay a small amount of silicone grease on the o-ring of the filter's base. If there is a trace of damage on the
o-ring, replace.
4. Remove the new A.C.-M.S. cartridge from its protective case. If the packaging is damaged or punctured do
not use it.
5. Lay a small amount of silicone grease on the o-ring of the new A.C.-M.S. cartridge.
6. Screw the new cartridge on the cartridge connector.
7. Clean the inside of the filter housing with a clean cloth.
8. Screw the filter housing carefully until securely fastened onto the base.
PARAMINA SA – Byway Evaggelistrias str. 19300 Aspropirgos, Greece, Tel: 0030 210 5575860
Fax: 0030 210 5575868, email:
04-2018 from s.n.1882761 edition
Active carbon – molecular sieve cartridge replacement