V
F
OICE
EATURES
• Integrates with FirstCommand Series. See DN-60772.
• Telephone applications require NFC-FFT.
H
-E
O
S
IGH
FFICIENCY
FFLINE
3.0 A P
S
(6.0 A
OWER
UPPLY
• 120 VAC (NFS-320/NFS-320C); 240 VAC (NFS-320E).
• Displays battery current/voltage on panel (with display).
®
F
S
I
LASH
CAN
NTELLIGENT
• Polls up to 318 devices in less than two seconds.
• Activates up to 159 outputs in less than five seconds.
• Multicolor LEDs blink device address during Walk Test.
• Fully digital, high-precision protocol (U.S. Patent 5,539,389).
• Manual sensitivity adjustment — up to nine levels.
• Pre-alarm ONYX intelligent sensing — up to nine levels.
• Day/Night automatic sensitivity adjustment.
• Sensitivity levels:
– Photo – 0.5 to 2.35%/foot obscuration.
– High-Sensitivity Photoelectric (VIEW
(0.5% - 2.0%/ft. obscuration), Special Applications (0.02%-
0.5%/ft. obscuration)
– Multi-Criteria Detector – Open Air Protection (2.52-3.89%/ft.
obscuration), Special Applications (1.13-2.52%/ft. obscuration)
• Drift compensation (U.S. Patent 5,764,142).
• Degraded mode: In the unlikely event that the NFS-320's primary
microprocessor fails, FlashScan detectors revert to degraded
operation and can activate the control panel's NAC circuits and
alarm relay. Each of the four built-in panel circuits includes a Dis-
able/Enable switch for this feature.
• Multi-detector algorithm involves nearby detectors in alarm deci-
sion (U.S. Patent 5,627,515).
• Automatic detector sensitivity testing (NFPA-72 compliant).
Up to 32 remote displays
FDU-80
LCD2-80
EIA-485
Sample
System
Options
Page 2 of 7 — DN-7112:P • 12/20/2020
WITCHING
A
)
IN
LARM
F
EATURES
®
) – Open Air Protection
FPTI-951
FSP-951
FST-951
FCO-951
...etc.
EIA-485
NFS-320
EIA-232
• Maintenance alert (two levels).
• Self-optimizing pre-alarm.
FSV-951 S
V
ERIES
IEW
H
-S
S
IGH
ENSITIVITY
MOKE
• Advanced ONYX intelligent sensing algorithms differentiate
between smoke and non-smoke signals.
• Addressable operation pinpoints the fire location.
• Ivory models (-IV) support CLIP mode as well as FlashScan.
• ULC listed models available; "A" models are ULC Listed.
• -R is retrofit, backwards compatible for use with older panels.
FCO-951/-IV A
DVANCED
• Detects all four major elements of a fire (smoke, heat, CO, and
flame).
• 135°F (57.2°C) fixed-temperature heat detector.
• Transmits an alarm signal due to heat.
• Separate signal for life-safety CO detection.
• Optional addressable sounder base for Temp-3 (fire) or Temp-4
(CO) tone.
• Automatic drift compensation of smoke sensor and CO cell.
• High nuisance-alarm immunity.
• ULC listed models available; -A models are ULC Listed.
FPTI-951(A) I
NTELLIGENT
• Combined photoelectric, thermal, and infrared sensor
• UL 268 7th Edition and UL 521 Listed; Canadian models CAN/
ULC S529 and CAN/ULC S530
• Microprocessor-based technology; combination photo, thermal,
and infrared technology.
FPC-951(A) P
HOTOELECTRIC
• Combined photoelectric and carbon monoxide sensor
SLC Intelligent Loop
DEVICES
NBG-12LX
FMM-1
IDC
2048 annunciator/control points
ACM-8R
ACM/AEM-24AT
Relay Control
LED Annunciator
Optional 318-point UDACT
PRN Series
Printer
®
(V
I
E
ERY
NTELLIGENT
D
ETECTOR
M
-C
F
/CO D
ULTI
RITERIA
IRE
M
-C
D
ULTI
RITERIA
ETECTOR
/CO S
ENSOR
FWSG
XP6/10
Input/Output Modules
FCM-1
NAC
FRM-1
Relay Contact
LDM-32
Custom Graphics
Dual phone
lines to
Central
Station
7112blok-2014.wmf
W
)
ARLY
ARNING
ETECTOR

Advertisement