Service Manual
REPAIR INFORMATION
1-28. VCOM_FFC_Styling
Note on Assembly
1.
Attach ①&② to the Bracket_Top.
2.
Connect ③ to the panel's Vcom PCB
connector.
3.
Put ③ through the clamp.
4.
Attach UL tape to cover the clamp
hole.
5.
Attach UL tape to the screw head.
DP-V3120
①
②
③
④
Panel Vcom PCB
⑤ UL tape
Parts No.
-
RFPC-25NV0B
①
-
TSB3509V0
②
DD2-0203-000
FPC, TCON, VCOM
③
(Expendable)
UL tape (white) 20mm×60mm
④
(Expendable)
UL tape (white) 20mm×30mm
⑤
31
REPAIR INFORMATION
Clamp
③
Description
Qty.
2
1
1
1