Ac Inlet Holder Detachment - Canon DP-V3120 Service Manual

Hide thumbs Also See for DP-V3120:
Table of Contents

Advertisement

3.7
AC Inlet holder Detachment
1. Unfasten the one Screw-A screws, and remove the Earth line of the AC Inlet Unit.
2. Unfasten the four Screw-B screws, and remove the AC/DC Inlet holder.
(The tightening torque for Screw-A is 100 N•cm.)
(The tightening torque for Screw-B is 100 N•cm.)
Mark
Parts No.
Washer
XD1-4200-402
Screw-A
XB6-7400-805
Screw-B
XB6-7300-405
Description
WASHER, TOOTHED LOCK, M4
SCREW, TP, M4X8
SCREW, TP, M3X4
Page 19
Earth line
(Washer、Screw-A)
Screw-B
Qty
1
1
4
Connector
Connector
Clamp
Clamp
Connector
Earth line

Advertisement

Table of Contents
loading

Table of Contents