  • Page 1 MAINTENANCE MANUAL...
  • Page 3: Table Of Contents

    Safety notes............................Alert levels and symbols in this manual....................Product description............................Structure ..............................Functional principle..........................Operation..............................Making settings using Geberit Service Handy..................Troubleshooting............................Deactivating automatic flush actuation ....................Maintenance ..............................Replacing the control..........................Replacing the lifting device........................Testing infrared user detection with manual flush actuation..............
  • Page 4: Safety

    Intended use The Geberit WC flush control with Sigma10 actuator plate is intended for flush actuation with Geberit Sigma concealed cisterns. Safety notes • Only use original spare parts when making repairs.
  • Page 5: Product Description

    Product description Structure Lifting device for Geberit Sigma concealed cistern 12 cm Lifting device for Geberit Sigma concealed cistern 8 cm Mounting frame Control Geberit actuator plate Sigma10 Power supply unit Battery compartment Functional principle Several IR sensors are located behind the actuator plate of the WC flush control. These sensors scan different detection ranges.
  • Page 6 Figure 1: Detection ranges User detection range Manual flush detection range Proximity detection range 4516380043 © 10-2018 966.335.00.0 (01)
  • Page 7: Operation

    The infrared interface for communication with the Geberit Service Handy is located in the middle of the actuator plate. To enable settings to be made, the Geberit Service Handy must be aimed at the infrared interface for communication from a distance of 20 to 30 cm and set to bidirectional mode.
  • Page 8 Start = <OK> – function is cancelled by re-establishing [Reinigung] releasing a flush. connection with the Geberit Service Handy. The LED in the sensor window flashes in 3-second cycles. Block flush. No flush is released. Function is cancelled upon re-establishing...
  • Page 9 Programs Menu item Description Application Value Factory [EN] setting [DE] Enable automatic flush. If this function is activated, the control On = <ON> [AutFlshEn] always releases a flush when the user Hygiene [ON] Off = <OFF> [AutFlshEn] steps back from the WC. Manual flush actuation is no longer necessary.
  • Page 10 Parameters Menu item Description Application Value Factory [EN] setting [DE] Set flush time. 0–4 [...] The flush volume of the partial flush Optimum flushing of the 0 = 2.5 l [FlshTime] can be set. (The specified flush 3.5 l [2] WC ceramic appliance 2 = 3.5 l [Spülzeit] volumes are reference values and 4 = 4.5 l...
  • Page 11 Counters Menu item Description Output [EN] [DE] Total number of days of operation. [Days?] [... ] days Displays the number of days of operation since commissioning. [SumBetrT?] Total number of uses. [Uses?] [... ] uses Displays the number of uses since commissioning. [SumBenut?] Total number of flushes.
  • Page 12: Troubleshooting

    The WC ceramic appliance is not Flush volumes set incorrectly ▶ Set the correct partial flush being flushed out properly. volume with the Geberit Service Handy. ▶ Check the power supply (mains Flush cannot be released. Network failure fuse).
  • Page 13: Deactivating Automatic Flush Actuation

    Deactivating automatic flush Disconnect the power supply cable from the actuation control for 10 seconds. The preset automatic flush actuation can be deactivated at any time. The procedure for activating automatic flush actuation is the same as for deactivating it. 5 single tones will sound to indicate that automatic flush actuation has been activated successfully.
  • Page 14 If necessary, screw in the screws on both sides of the actuator plate. To test that automatic flush actuation has been deactivated, place your hand at a distance of 2–3 cm from the actuator plate. 4516380043 © 10-2018 966.335.00.0 (01)
  • Page 15: Maintenance

    Maintenance Disconnect both cables from the control. Replacing the control Loosen any screws that may be present on both sides of the actuator plate. Extract the control. Remove the actuator plate. Insert the new control. 4516380043 © 10-2018 966.335.00.0 (01)
  • Page 16 Reconnect the cable on the right-hand side Mount the actuator plate. to the control and hook the excess cable into the cable suspension. If necessary, screw in the screws on both sides of the actuator plate. Reconnect the power supply cable on the left-hand side to the control.
  • Page 17: Replacing The Lifting Device

    Replacing the lifting device Remove the tension wedge. Loosen any screws that may be present on both sides of the actuator plate. Remove the actuator plate. Disconnect both cables from the control. Turn the distance bolts. 4516380043 © 10-2018 966.335.00.0 (01)
  • Page 18 Turn the actuator rod anticlockwise. Extract the lifting device. Remove the protective foil from the new lifting device. Extract the mounting frame. Mount the new lifting device. Extract the protection plate. Mount the protection plate. 4516380043 © 10-2018 966.335.00.0 (01)
  • Page 19 Mount the mounting frame. Secure the tension wedge in place. Secure the distance bolts in place. Turn the actuator rod clockwise. 4516380043 © 10-2018 966.335.00.0 (01)
  • Page 20 Reconnect the cable on the right-hand side Mount the actuator plate. to the control and hook the excess cable into the cable suspension. If necessary, screw in the screws on both sides of the actuator plate. Reconnect the power supply cable on the right-hand side to the control.
  • Page 21: Testing Infrared User Detection With Manual Flush Actuation

    ▶ Never use cleaning agents that contain chlorine or which are acidic, abrasive or corrosive. Geberit recommends the Geberit AquaClean cleaning set (art. no. 242.547.00.1). Clean the surfaces with a soft cloth and a mild liquid cleaning agent.
  • Page 22 4516380043 © 10-2018 966.335.00.0 (01)
  • Page 23 4516380043 © 10-2018 966.335.00.0 (01)
  • Page 24 Geberit International AG Schachenstrasse 77, CH-8645 Jona documentation@geberit.com www.geberit.com 4516380043 © 10-2018 966.335.00.0 (01)