Safety Target group Maintenance and repair on this product may only be performed by skilled persons. Safety notes • Use only original spare parts when making repairs • Do not modify the product or add any additional modules Explanation of symbols Table 1: Symbols in the instructions Symbol...
Functional principle Several IR sensors are located behind the actuator plate of the WC flush control. These sensors scan different detection ranges. The user detection range (1) measures whether a user is sitting or standing in front of the WC flush control. If a sitting user is detected, manual flush actuation is deactivated.
The infrared interface for communication with the Geberit Service Handy is located in the middle of the actuator plate. To make any settings, the Geberit Service Handy must be aimed at this area from a distance of 20 to 30 cm.
Page 7
42 [CleanTime] [ReiniZeit]. The function is cancelled by re- establishing connection with the Geberit Service Handy. The LED in the sensor window flashes in three- second cycles Block flush. In the event of detection Start = <OK>...
Page 8
Table 3: Programs Menu item Description Application Adjustment Factory [EN] range setting [DE] Enable automatic flush. Hygiene On = [ON] [ON] [AutFlshEn] If this function is activated, the Off = [OFF] [AutFlshEn] control always releases a flush when the user steps back from the WC. Manual flush actuation is no longer necessary Activate manual flush...
Page 9
Table 4: Parameters Menu item Description Application Adjustment Factory [EN] range setting [DE] Set flush time. Optimum flushing of the 0–4 [...] 3,5 l [2] [FlshTime] The flush volume of the partial flush WC ceramic appliance 0 = 2,5 l [Spülzeit] can be set.
Page 10
Table 5: Counters Menu item Description Output [EN] [DE] Total number of days of operation. [...] days [Days?] Displays the number of days of operation since commissioning [SumBetrT?] Total number of uses. [...] uses [Uses?] Displays the number of uses since commissioning [SumBenut?] Total number of flushes.
Deactivating automatic flush actuation The preset automatic flush actuation can be deactivated at any time. This change can be carried out by the operator or user. Prerequisites In order to interrupt the power supply, the actuator plate must be removed. A size 2 hexagon key is included for this purpose.