3 Setup and installation

Introduction to the VisualEyes™ 505 software suite
VisualEyes™ 505 combines cutting-edge technology with touch-screen capability in a streamlined software
interface. VisualEyes™ 505 provides information to assist in the evaluation, diagnosis and
documentation of vestibular disorders. Eye movements are recorded by use of a goggle mounted with one or
two infrared video cameras. The eye images are displayed in real time in high resolution on a computer monitor.
External environments (room) are recorded by use of an integrated / external USB camera if desired. Patient
interviews are recorded separately for recording medical histories. This information can then be used by a
trained medical professional to assess vestibular disorders.
Installation of OtoAccess® Database and VisualEyes™ 505 software
If the computer is purchased from Interacoustics, all the software / databases / drives (e.g: OtoAccess®
Database, VisualEyes™ 505) are pre-installed. If the operator wants to install these in any other computer or in
the event of re-installation, the following procedures are to be followed for successful installation.
3.2.1
OtoAccess® Database installation
The VisualEyes™ 505 software is accesssed through OtoAccess® Database. OtoAccess® Database is used to
store patient information and data recordings.
If the operator wants to install OtoAccess® Database in any computer (not of interacoustics) or in the event of
re-installation, please read the instructions for use that are included with the OtoAccess® Database installation
media (CD or flash drive) or contact your distributor.
3.2.2
VisualEyes™ 505 software installation
If the computer is purchased from Interacoustics, all the software / databases / drives (e.g: OtoAccess®
Database, VisualEyes™, rotational chair drivers) are preinstalled. If the customer wants to install VisualEyes™
software in any other computer or in the event of re-installation, the following procedure is to be followed for
successful installation.
NOTICE
OtoAccess® Database must be installed prior to installing VisualEyes™ 505.
Ensure that the chosen computer is compliant with all minimum PC requirements (refer to section 6.1). To install
the VisualEyes™ software, run the Micromedical VisualEyes™ Installer.exe file from the VisualEyes™
installation media.
NOTICE: As a part of data protection, ensure to be compliant to all the following points.
1.
Use Microsoft supported operating systems
2.
Ensure operating systems are security patched
3.
Enable database encryption
4.
Use individual user accounts and passwords
5.
Secure psychical and network access to computers with local data storage
6.
Use updated antivirus and firewall and anti-malware software
7.
Implement appropriate backup policy
8.
Implement appropriate log retention policy