QTM - eLED+DMX
Connecting &
Connecting and configuring the LINEARdrive 100D/180D
DMX in shield
DMX in -
Ext in -
DMX in +
Ext in +
Primary Wiring
GND
NEU
HOT
Secondary Wiring
TC
LED supply +
Group
1
Group
2
Group
3
Group
4
Black Wire = +24V
Red Wire = Red LED
Green Wire = Green LED
-
+
Blue Wire = Blue LED
M
White Wire = White LED
WARNING:
Risk of electrical shock. May result in serious injury or death. Disconnect power before servicing or installing.
CAUTION:
The device may only be connected and installed by a qualified electrician. All applicable regulations, legislation and building codes must be observed.
Incorrect installation of the device can cause irreparable damage to the device and the connected LEDs.
DMX Shield must be grounded to Earth Ground at a single point external to power supply
© 2020, Q-Tran Inc. 155 Hill St. Milford, CT 06460. All rights reserved - 203-367-8777 - sales@q-tran.com - www.q-tran.com
To DMX Controller
LedSync shield
LedSync thru -
Ext in -
LedSync thru +
Ext in +
GND
HOT
NEU
Configuration
W B G R +24
LED
Blue Wire = Blue LED
Red Wire = Red LED
Green Wire= Green LED
White Wire = White LED
Black Wire = +24V
W B G R +24
Red
DMX +
Blue
DMX -
Green
GND
Commonly Asked Questions
1) How can I verify my installation?
● Apply AC input, verify display turns on : This confirms AC input wiring
● Run "Visual Test Run" : This verifies wiring of LEDs. Make sure LEDs turning on go in
same order as the Test Run
2) I don't have a controller yet, how can I keep my lights on?
● Change the Mode to "COLR" : This allows to manually set a specific color to be on
● Adjust the Hue or WHIT to achieve the desired color : This sets that specific color
3) My LEDs aren't coming out the right color. They look like white has been added in
● Verify the Network Resolution "NETW RES" : Default is 8 BT
● Check your DMX Programming. Stick controllers come with RGB programs by default.
This will cause RGBW LEDs to show Pink vs. Red
Control Wiring
DMX connections
LedSync shield
LedSync thru -
LedSync thru +
DMX in shield
DMX in shield
DMX in -
DMX in +
DMX in -
DMX in +
Instruction
LED DRIVER 2
(120 - 277V)
DMXIN DMXOUT
A
B
C
DMXOUT DMXIN
To next
power
supply
DMX Shield
DMX -
DMX +
SECONDARY
PRIMARY
LED DRIVER
(120 - 277V)
GND
HOT
NEU
4