Troubleshooting; Fault Table; Maintenance - STIEBEL ELTRON HDB-E 12 Si Operation And Installation

Electronically controlled comfort instantaneous water heater
Hide thumbs Also See for HDB-E 12 Si:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 16
INSTALLATION

Troubleshooting

13. Troubleshooting
WARNING Electrocution
To test the appliance, it must be supplied with power.

13.1 Fault table

Fault / LED diagnostic traffic light signal Cause
The appliance does not start.
The flow rate is too low.
The temperature is not achieved.
The heating system does not switch on.
No hot water and no traffic light display.
No hot water at flow rate of > 2.3 l/min.
Traffic light display: green flashing.
No hot water at flow rate of > 2.3 l/min.
Traffic light display: yellow constantly on; green
flashing.
No hot water.
Traffic light display: red constantly on; green flashing.

14. Maintenance

WARNING Electrocution
Before any work on the appliance, disconnect all poles
from the power supply.
Draining the appliance
The appliance can be drained for maintenance work.
WARNING Burns
Hot water may escape when you drain the appliance.
f Close the shut-off valve in the cold water inlet line.
f
f Open all draw-off valves.
f
f Undo the water connections on the appliance.
f
f Store the dismantled appliance in a room free from the risk
f
of frost, as water residues remaining inside the appliance can
freeze and cause damage.
26
| HDB-E Si
Indicator options for diagnostic traffic light (LED)
The shower head/aerators are scaled up.
The strainer in the appliance is dirty.
One phase down.
The air sensor detects the presence of air in the water
and briefly switches the heater off.
The MCB/fuse has responded/blown.
The safety pressure limiter (see chapter "Installation /
Specification / Wiring diagram" has switched off.
The PCB is faulty.
The PCB is faulty.
The flow sensor is not plugged in.
The flow sensor is faulty.
The high limit safety cut-out has responded (see
chapter "Installation / Specification / wiring diagram"
or has suffered a break in continuity.
The heating system is faulty.
The PCB is faulty.
The cold water inlet temperature exceeds 35 °C.
The cold water sensor is faulty.
Red
Illuminates in the event of a fault
Yellow
Illuminates during heating operation
Green
Flashing: Appliance connected to
power supply
Remedy
Descale or if necessary replace the shower head /
aerators.
Clean the strainer.
Check the fuse/MCB in your fuse box/distribution
board.
The appliance restarts after one minute.
Check the fuse/MCB in your fuse box/distribution
board.
Remove the cause of the fault (e.g. faulty pressure
washer).
Protect the heating system against overheating by
opening a draw-off valve downstream of the appli-
ance for one minute. This depressurises and cools
down the heating system. Activate the safety pressure
limiter at flow pressure by pressing the reset button,
also see chapter "Installation / Commissioning / Ini-
tial start-up".
Check the PCB and replace if required.
Check the PCB and replace if required.
Re-insert the flow sensor plug.
Check the flow meter/flow sensor and replace if re-
quired.
Check the high limit safety cut-out and replace it if
required.
Check the resistance of the heating system, and re-
place if required.
Check the PCB and replace if required.
Reduce the cold water inlet temperature to the ap-
pliance.
Check the PCB and replace if required.
www.stiebel-eltron.com