Mechanical Stopper Adjustment; Maintenance - RIB KIT KING 24V Manual

Hide thumbs Also See for KIT KING 24V:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 27
G
B
MECHANICAL STOP - OPTIONAL
Code ACG8089
Optional mechanical stop to stop closing, if the gate is not fitted with a floor stop (Fig. 8).

MECHANICAL STOPPER ADJUSTMENT

To adjust the stoppers you have to follow the scheme (Fig. 9).
To set the opening limit it's enough to fix the stopper (A) in the needed position by
tightening the 8mA screw with a n. 13 key.
To obtain the desired closing limit you must adjust the stopper (B) (OPTIONAL) ) in the
needed position and tighten it as for stopper (A).

MAINTENANCE

To be undertaken only by specialized staff after disconnecting power supply.
Lubricate the hinges and check the oil level and thrust force generated by the operator
on the gate once a year.
Lubricate the nut screw with silicon grease every two years.
30
8
9
10

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kit king 24v wi-fiAd00709Ad00716

Table of Contents