MECHANICAL STOPPER - OPTIONAL (Code ACG8088)
Optional mechanical stopper to stop the closing, if the gate is not fitted with a floor stopper.

MECHANICAL STOPPER ADJUSTMENT

To adjust the stoppers you have to follow the scheme (Pic. 11).
To set the opening limit it is enough to fix the stopper (A) in the needed position by tightening
the 8mA screw with a n. 13 key.
To obtain the desired closing limit you must adjust the stopper (B) (OPTIONAL) in the needed
position and tighten it as for stopper (A).

MAINTENANCE

Maintenance should be carried out by skilled and qualified staff only, after switching off the
mains supply.
Regularly lubricate the hinges of the gate every 6 months and keep the thrust needed to move
the gate leaf monitored (according to EN12453).

ELECTRIC CONNECTIONS