The factory default configuration for the STS400™ is given here for reference:
MASTER READER CONFIGURATION
The following gives an excerpt of the relevant configuration parameters
 READING SYSTEM LAYOUT:
 Device Network Setting = Alone o ID-NET
 Topology Role = Master (synchronized)
 Expected Slave Device = xx
 Link Failure Timeout (ms) = 10000
 OPERATING MODES:
 Operating Mode = Phase Mode
 Reading Phase ON = Ext. Trigger Leading Edge
 Acquisition Trigger = Continuous
 Reading Phase OFF = Input 2 Trailing Edge, Complete Read
 Image Acquisition Buffer Size = 20
 CALIBRATION
 Exposure Time (x10us) =
 Gain =
 Gain Increasing = x1
 IMAGE PROCESSING
 Processing Mode = Advanced Code Setting
 Image Processing Timeout (ms)  100
 1D CODES:
 Minimum Code Height (mm) = 5
 Tires Improvement = Method 2 (Sigma ROI) to optimize code location and
minimize processing time in case of low height barcodes
 Code search priority = Horizontal/Vertical (even and odd Slave nodes alternate
Horizontal/Vertical and 45 Degrees) to optimize code location in case of low
height barcodes
 DATA COLLECTION
 Minimum Phase Duration (ms) = (presence sensor debounce filter may be
modified to eliminate false reading Phases)
Actual Calibration default parameter
values depend on STS400™ model and
can be modified to improve reading rate
in the specific application.