</message>
<message>
</message>
<message>
.....
</message>
</context>
</TS>
5.3
Configuring the function display at user-specific keys (U keys)
Function
Active functions can be displayed at the configurable user keys via the PLC. For instance, small
LEDs can be emulated on the softkeys.
You configure the function in the "slckcpf.ini" file.
Interface signals
The PLC bits are in the output image of the PLC/HT 10 interface and are analogous to those in the
input image.
Signals to the MCP1 (or MCP2)
Interface PLC → HT 10
Byte
AB n + 1
AB n + 4
AB n + 5
Handheld Terminal HT 10
Equipment Manual, 09/2020, A5E47430965B AA
<source>SK_USERKEY1</source>
<comment></comment>
<translation>U1</translation>
<remark>User key 1</remark>
<chars>10</chars>
<lines>2</lines>
<languageIndependent>true</languageIndependent>
<source>SK_USERKEY2</source>
<comment></comment>
<translation>U2</translation>
<remark>User key 2</remark>
<chars>10</chars>
<lines>2</lines>
<languageIndependent>true</languageIndependent>
Bit 7
Bit 6
U4
U9
U10
U8
5.3 Configuring the function display at user-specific keys (U keys)
Bit 5
Bit 4
U3
U11
U12
U7
U6
Commissioning
Bit 3
Bit 2
Bit 1
U2
U1
U13
U14
U15
U5
Bit 0
U16
67