4.3 Pairing (Only High-code Models)

4.3.1 Initial Pairing Setting

For the high-code model (SG-P20□-□) of this device, the pairing between the switch body and
the actuator is not set as default (factory settings). Before using the product, make sure to let
the switch body detect the actuator to implement the pairing.
● The high-code model (SG-P20□-□) of this device cannot be used unless the pairing is
implemented.
The following section describes the procedure for paring the standard unit SG-P20□-M-□ and
the actuator.
1.
Wire the SG-P20□-M-□ and turn ON the power supply.
SG-P20□-M-P (PNP output)
SG-P20□-M-N (NPN output)
Note 1: Using only one switch body
2.
When the power is turned ON, the SG-P20□-M-□ transitions to the pairing mode and the
indicator blinks in yellow.
3.
After transitioning to the pairing mode, make the SG-P20□-M-□ detect the actuator you
want to pair to establish pairing between them. When the actuator is detected, the indicator
blinks in green. In three seconds after the actuator is detected, the indicator is lit in green to
indicate that the pairing has been established.