7.1 Specifications

7.1 Specifications

7.1.1 Model No.

(Note 1)
Provided only on the SG-P□□-M standard unit.

7.1.2 Individual Specifications

Model
Operating distance Front / Side
Power supply voltage
Current consumption
Control output (OSSD1 / 2)
Operation mode (output
operation)
7-2
Standard PNP output
SG-P□□-M-P
Sao (OFF→ON): 5 mm, Sar (ON→OFF): 15 mm
24V DC +10%/ -20% ripple (P-P) of 10% or less
PNP transistor
● Open collector 2
outputs
Maximum source current:
100 mA
● Applied voltage: Same as the power supply
voltage
(PNP:between control output and 0V,
(Note 2)
NPN:between control output and +V)
● Residual voltage: 2V or less (source current and
sink current: 100 mA)
(excluding voltage drop due to cable)
● Leakage current: 0.2 mA or less (including power
OFF state)
● Maximum load capacity: 0.47 μF
● Load wiring resistance: 3 Ω or less
When the actuator is detected (safe state): ON
When the actuator is not detected (unsafe state or
lockout state): OFF
When the switch body (sub) does not detect actuator
(series connection): OFF
Standard NPN output
SG-P□□-M-N
30 mA or less
NPN transistor
● Open collector 2
outputs
Maximum sink current:
100 mA
Sub
SG-P□□-S
20 mA or less
-
-
-
-
WUME-SGPUM-2